3
Attach blower plate
Attach the one or two blower unit mounting
screw(s)
and then the one or several blower
f
plate mounting screw(s)
Blower unit
b
Knockouts
c
Back plate
e
4
Insert the tabs on each side of the damper
into the holes at the inside rear of the
adapter. Attach the exhaust adapter
blower plate
with the two tapping screws
b
provided. Make sure that the damper
swings freely.
WARNING
• Fire hazard! Correctly install the vent fan before
use.
When changing the vent fan position for wall
venting or roof venting:
• Properly align the ventilation fan openings and
blower plate knockouts.
• Ventilation fan openings should be completely
exposed to the outside.
• After installation, check the air ventilation path.
Refer to step 2 for proper vent selection.
Improper installation can cause problems such as:
• Inability to assemble the blower plate or
ventilation motor correctly
• Abnormal noise during product operation
• Weak ventilation
• Product overheating and the possibility of
product breakdown or fire
to microwave oven.
d
.
a
to the
a
c
Step 4: Prepare the Wall and Upper
Cabinet
WARNING
• To avoid personal injury or property damage, do
not attempt to install this microwave oven if you
cannot find a wall stud. Consult a carpenter or
contractor.
Measure and Attach Templates
1
Using a plumb line and (metal) measuring
tape, find and mark the vertical center line on
the back wall of the opening.
2
Find and mark one or two points where the
studs are on the wall. (Studs are normally 16
inches apart.) Then measure and mark the
stud locations. If you cannot find any wall
studs, consult a local building contractor.
3
Draw a vertical line on the wall at the center of
the 30" wide opening.
NOTE
• Be sure the minimum width is 30 inches.
4
Center the rear wall template
by lining up the plumb line on the wall with
the centerline on the template. Then securely
tape or tack the rear wall template in place.
Make sure the minimum width is 30 inches
and that the top of the rear wall template is
located a minimum of 30 inches above the
cooking surface.
Measure the bottom of the upper cabinet
frame. Trim edges A, B, and C on the upper
cabinet template
so that the template will
a
fit on the bottom of the upper cabinet. If the
upper cabinet has a recessed frame, trim the
template so it fits inside the recessed area. If
needed, the template can be trimmed inside
INSTALLATION
11
in the space
b