StarDot Technologies netcam XL User Manual page 37

Stardot technologies netcam xl user's manual
Table of Contents

Advertisement

unsure if you need passive mode, it is usually safe to enable it anyway.
Default: On
Timeout
If the FTP process hasn't completed within the time specified here,
the Express 1 will attempt to restart the process.
Default: 120
UPLOAD VIA SMTP (EMAIL)
If you prefer the event-triggered image captures be e-mailed, select
this option. If you've enabled a large number of images, this can add up
to a large e-mail attachment.
Mail To
Specify the e-mail address you prefer NetCam to send the images to.
Mail From
Specify a "from" e-mail address. This can be created.
TRIGGER SENSOR CONNECTOR
To connect a simple sensor (i.e. a door contact switch), connect
one lead into the appropriate I/O port (pins 3 or 4), and the other lead
into the Ground connector (pin 8). The connector is internally biased.
If you need to use I/O ports 3 or 4 (pins 5 or 6), they require a 680 ohm
resistor biased to +5V connector (pin 7). When the sensor makes a
contact closure, NetCam will detect it and buffer images for email or FTP
transfer.
1,2 = Relay, 2A@28VDC or 0.5A@125VAC
3 = I/O #1
4 = I/O #2
5 = I/O #3
6 = I/O #4
7 = +5V, 50mA Max
8 = Ground