TABLE OF CONTENTS Table of contents User and safety instructions ....................4 User information ....................... 4 Safety instructions ......................5 System overview: iV-Light ventilation device ............... 8 Construction ........................9 Function ........................... 10 Control elements ......................12 Preparing for installation ......................14 Installation position ......................
Action required: This prompts the user to perform a specific action. Check the results requires you to check the results of the action you have performed. Action focus: To be taken into account in the corresponding assembly step. iV-Light ventilation device | Installation instructions...
Non-observance of safety instructions could result in injury and/or property damage. These installation instructions only cover the standard variant (referred to as the "Standard variant" in the following text) of the iV-Light ventilation device. Information on the variants can be found in the separate installation instructions for the respective components.
Page 6
• When using several ventilation devices controlled by several controllers, you must ensure that the ventilation devices are synchronised with each other (see installation and operating instructions for controllers). You should connect all controllers via a mains fuse in the house distribution board. iV-Light ventilation device | Installation instructions...
Page 7
The ventilation device complies with the technical safety requirements and standards of electrical appliances for domestic use. It conforms to current European Union and United Kingdom directives. The full text of the EU declaration of conformity is available at the following Internet address: https://www.inventer.eu/downloads/ . iV-Light ventilation device | Installation instructions...
SYSTEM OVERVIEW: IV-LIGHT VENTILATION DEVICE System overview: iV-Light ventilation device The iV-Light ventilation device is designed to ventilate living rooms and bedrooms in single- and multi-family houses, hotels and guest houses, rooms in public facilities and work rooms in office buildings.
The most important components of the iV system are the ceramic thermal accumulator, the reversing fan, air guiding vanes for straightening the air volume flow, filters for different hygienic requirements, a closable inner cover and an outer cover. A control device (controller) completes the system. iV-Light ventilation device | Installation instructions...
Page 11
SYSTEM OVERVIEW: IV-LIGHT VENTILATION DEVICE Ventilation device iV-Light The iV-Light ventilation devices are used to provide ventilation for living rooms and bedrooms. An integrated ceramic thermal accumulator ensures optimum heat recovery. It is a ventilation device with simple airflow and works according to the principle of heat recovery by changing the direction of the fan.
• Cable • Cable External interface 1 potential-free switching 1 potential-free switching contact per control module: contact per controller: Pressure switch (NC) Pressure switch (NC) • • Other sensors (NO) Other sensors (NO) • • iV-Light ventilation device | Installation instructions...
Page 13
Clust-Air module (max. 4) controller platform (zone division Pressure switch (NC/NO) and number of sensors per zone • Other sensors (NO) arbitrary) • For detailed information, see the controller's installation and operating instructions. iV-Light ventilation device | Installation instructions...
1,2 m – 0,75 y 1,2 m 1,2 m Installation over corner 1,0 m 1,0 m 1,4 m 1,0 m 1,0 m 1,4 m 1,2 m – 0,75 y 1,2 m – 0,75 y iV-Light ventilation device | Installation instructions...
Ø Position of wall opening Position of Simplex wall installation system Figure 2: Dimensioned drawing of the iV-Light wall opening (interior view) 1 Wall opening (Fig. 2, left) 3 Outer edge of reveal (insulation with Simplex wall installation system (Fig. 2, right)
For sectional drawings of other variants of your ventilation device, see the installation instructions for your specific external termination. Sectional drawing of the iV-Light ventilation device 1 – 2° ≥ 290 Figure 3: Sectional drawing of the iV-Light ventilation device A Interior plaster/ interior structure C Insulation B Masonry D Render...
► Create an opening for the flush-mounted housing on the interior wall, centred on the core drill hole,for installing the inner cover. Dimensions: 245 x 245 x 40 (W x H x D, mm) iV-Light ventilation device | Installation instructions...
NYM-J 3x1.5 mm² (Connect inner cover) RS485 data cable, Unit communication Easy Connect e16 operating device e. g.: (only if the system compo- Type J-Y(ST)Y 2x2x0.8 mm² nents communicate by cable [otherwise radio]) iV-Light ventilation device | Installation instructions...
Page 21
Length max. 500 m System communication by radio: Cable NYM-J, wire cross-section 1.5 mm² House distributor Operating device: Control device: Control device: Easy Connect e16 Connect inner cover Connect inner cover Ventilation device n Ventilation device 1 iV-Light ventilation device | Installation instructions...
► Cut the wall sleeve to the determined dimension X + a protrusion of Y on the exterior wall. Be careful not to cut away the cut-out for the ventilation device connecting cable. ► File the edges. iV-Light ventilation device | Installation instructions...
Page 23
• Before foaming the free space between the wall sleeve and masonry, insert styrofoam discs. ► Insert the styrofoam discs into the wall sleeve from the inside and outside. iV-Light ventilation device | Installation instructions...
Page 24
Flush with the exterior wall Flush with the exterior wall • • 30 mm 30 mm 30 mm Take care not to damage the connecting cable on the interior wall. The wall sleeve is installed. iV-Light ventilation device | Installation instructions...
Both ends of the end-stop tape are located above the horizontal central axis, so that the fixing claws on the weather protection grille are able to hook into the wall sleeve on the left and right. iV-Light ventilation device | Installation instructions...
Page 26
The fixing claws hook into the wall sleeve. ► Seal the joint between the panel and the exterior wall all the way around with a permanently elastic exterior sealant. (2) The weather protection grille is installed. iV-Light ventilation device | Installation instructions...
► Insert the inVENTron from the interior into the Standard wall sleeve so that you can reach the BUS plug Slim connection. The narrow Slim guiding vane [16 mm] is aligned towards the interior. The thermal accumulator insert has been inserted. iV-Light ventilation device | Installation instructions...
Electrical connection of the reversible fan The function of the iV-Light ventilation system requires the simultaneous operation of two iV-Light ventilation units in push-pull mode. This section therefore describes the connection of a pair of units, not a single unit.
Page 29
5 Clamping screws on the controller plug-in 2 Plug-in connector on the fan cable connector 3 Plug-in connector on the controller cable 6 Clamping screws on the fan plug-in 4 Fan BUS [to controller] connector iV-Light ventilation device | Installation instructions...
► Make sure that all reversible fans rotate in the direction appropriate to their connections. Start direction extract air mode Start direction supply air mode Direction of fan clockwise Direction of fan counter clockwise inVENTron is connected and installed iV-Light ventilation device | Installation instructions...
4 corner drill holes in the inner cover base plate. ► Pull the panel forwards at the upper edge until you feel locking hook snap into place. The inner cover is installed. iV-Light ventilation device | Installation instructions...
Sensitivity of the air flow at ± 20 Pa (EN 13141-8) Electrical protection area Outside protection areas 0 – 2 (in accordance with VDE 0100) Automatic by reversing operation Frost protection (down to -20 °C) Conformity iV-Light ventilation device | Installation instructions...
• Energy efficiency class (SEC class) • Sound power level L • Maximum air flow (supply air) Demand-controlled Manually controlled Pure with sensor sMove with sensor Pure without sensors Easy Connect e16 sMove without sensor MZ-Home iV-Light ventilation device | Installation instructions...
TECHNICAL DATA Specifications according to ErP Directive, Regulation 1254/2014 iV-Light ventilation device, demand-controlled: iV-Light product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014 Description Values Supplier inVENTer GmbH Model identifier iV-Light Cold -85.671 SEC class / Specific Energy Average -42.513...
Page 35
TECHNICAL DATA iV-Light ventilation device, manually controlled: iV-Light product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014 Description Values Supplier inVENTer GmbH Model identifier iV-Light Cold -78.012 SEC class / Specific Energy Average -36.847 Consumption (SEC) [kWh/(m²a)] Warm -13.265...
In connection with the Connect controller platform, the inner cover is not part of the scope of delivery. The Connect inner cover is ordered as part of the Connect controller platform and replaces the Light or Undercover manual inner cover. iV-Light ventilation device | Installation instructions...
Check the connector plug on the Supply air is cold controller. The connector plug must be sitting firmly in the connector housing. The controller is operating in Select heat recovery mode on the ventilation mode. controller. iV-Light ventilation device | Installation instructions...
To order components for your ventilation device, contact your nearest distributor or our service staff. Technical customer service For technical support contact our service staff: +49 (0) 36427 211-0 +49 (0) 36427 211-113 info@inventer.de http://www.inventer.eu iV-Light ventilation device | Installation instructions...