Inverter iV14-MaxAir Installation Instructions Manual

Inverter iV14-MaxAir Installation Instructions Manual

Ventilation device with heat recovery

Advertisement

Quick Links

Installation instructions
iV14-MaxAir
Ventilation device
with heat recovery
www.inventer.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iV14-MaxAir and is the answer not in the manual?

Questions and answers

Summary of Contents for Inverter iV14-MaxAir

  • Page 1 Installation instructions iV14-MaxAir Ventilation device with heat recovery www.inventer.eu...
  • Page 2 GmbH Phone: +49 (0) 36427 211-0 Ortsstraße 4a Fax: +49 (0) 36427 211-113 07751 Löberschütz E-mail: info@inventer.de Germany Web: www.inventer.eu CEO: Annett Wettig VAT ID number: DE 815494982 Jena District Court HRB 510380 iV14-MaxAir ventilation device | Installation instructions...
  • Page 3: Table Of Contents

    Table of contents User and safety instructions ....................4 User information ......................4 Safety instructions ......................5 System overview: iV14-MaxAir ventilation device ............... 8 Construction ........................9 Function ......................... 10 Control elements ......................12 Preparing for installation ......................14 Installation position......................14 Position of the wall opening ...................
  • Page 4: User And Safety Instructions

    Action required: This prompts the user to perform a specific action. ► Check the results requires you to check the results of the action you have performed.  Action focus: To be taken into account in the corresponding assembly step. iV14-MaxAir ventilation device | Installation instructions...
  • Page 5: Safety Instructions

    USER AND SAFETY INSTRUCTIONS Safety instructions The installation instructions are part of your iV14-MaxAir ventilation device and must be available at all times (see www.inventer.eu/downloads). When handing the system to a third party, the information regarding access to the installation instructions must be handed over also.
  • Page 6 You should connect all controllers via a mains fuse in the house distribution board. If your device has a fault, contact your nearest distributor or our technical service. Any kind of use other than the intended use will exclude all liability claims. iV14-MaxAir ventilation device | Installation instructions...
  • Page 7 The ventilation device complies with the technical safety requirements and standards of electrical appliances for domestic use. It conforms to current European Union and United Kingdom directives. The full text of the EU declaration of conformity is available at the following Internet address: https://www.inventer.eu/downloads/ . iV14-MaxAir ventilation device | Installation instructions...
  • Page 8: System Overview: Iv14-Maxair Ventilation Device

    (white/grey/anthracite/ custom colour). • Nordic variant: iV14-MaxAir Nordic variants (in the further text "Nordic variant") for the integra- tion of the external termination in clinker brick walls (white/grey/anthracite/custom colour).
  • Page 9: Construction

    SYSTEM OVERVIEW: IV14-MAXAIR VENTILATION DEVICE Construction Standard variant Flex Figure 1: Overview of the iV14-MaxAir ventilation device Components External termination: Thermal accumulator insert Flex weather protection hood (thermal accumulator, inVENTron) 1 Weather protection hood cover 6 Thermal accumulator with insulation...
  • Page 10: Function

    The most important components of the iV system are the ceramic thermal accumulator, the reversing fan, air guiding vanes for straightening the air volume flow, filters for different hygienic requirements, a closable inner cover and an outer cover. A control device (controller) completes the system. iV14-MaxAir ventilation device | Installation instructions...
  • Page 11 SYSTEM OVERVIEW: IV14-MAXAIR VENTILATION DEVICE Ventilation device iV14-MaxAir The iV14-MaxAir ventilation device is used to provide ventilation for living spaces and living space- like commercial premises. An integrated ceramic thermal accumulator ensures optimum heat recovery. The iV14-MaxAir ventilation device is a ventilation device with simple airflow and works according to the principle of heat recovery by changing the direction of the fan.
  • Page 12: Control Elements

    Cable Cable External interface 1 potential-free switching 1 potential-free switching con- contact per Control module: tact per controller: Pressure switch (NC) Pressure switch (NC) • • Other sensors (NO) Other sensors (NO) • • iV14-MaxAir ventilation device | Installation instructions...
  • Page 13 Device communication Cable External interface 1 potential-free switching contact per Clust-Air module (max. 4) Pressure switch (NC/NO) • Other sensors (NO) • For detailed information, see the controller's installation and operating instructions. iV14-MaxAir ventilation device | Installation instructions...
  • Page 14: Preparing For Installation

    1,2 m – 0,75 y 1,2 m 1,2 m Installation over corner 1,0 m 1,0 m 1,0 m 1,0 m 1,4 m 1,4 m 1,2 m – 0,75 y 1,2 m – 0,75 y iV14-MaxAir ventilation device | Installation instructions...
  • Page 15: Position Of The Wall Opening

    ≥ 250 Ø Position of wall opening Position of Simplex wall installation system Figure 2: Dimensioned drawing of the iV14-MaxAir wall opening (interior view) 1 Wall opening (Fig. 2, left) 3 Reveal Simplex wall installation system (Fig. 2, right) 4 Door/window frame...
  • Page 16: Sectional Drawing Of The Ventilation Device

    Sectional drawing of the iV14-MaxAir ventilation device, standard variant 1 – 2° Wandstärke ≥ 280 Figure 3: Sectional drawing of the iV14-MaxAir ventilation device with Flex weather protection hood A Interior plaster/ interior structure C Insulation B Masonry...
  • Page 17: Dimensional Drawings Of Components

    Figure 5: Dimensional drawing of the Flair V-233x233 inner cover white SDE 1 Inner cover panel 4 Inner cover base plate 2 Sound insulation insert SDE (optional) 5 Spacer (4 x) 3 Retaining plate IB V-233x233 6 Interior wall fixing hole (4 x) iV14-MaxAir ventilation device | Installation instructions...
  • Page 18: Installation And Assembly

    3 d: Slim guiding vane (16 mm) 3 e: BUS plug connection Flair inner cover 4 a: Interior wall fixing material 4 b: ISO Coarse 60 % dust filter WSH = Weather protection hood iV14-MaxAir ventilation device | Installation instructions...
  • Page 19: Create Wall Opening

    The wall sleeve must have a slope of 1 – 2° to the exterior wall side. Alternatively the drilling can be carried through with a slope. The wall opening for the ventilation device has  been created. iV14-MaxAir ventilation device | Installation instructions...
  • Page 20: Laying The Cables To The Wall Opening Of The Ventilation Device

    Cable origin Pure Operating voltage fan Stranded cable Pure control module and device 6 – 16 V DC, sMove sMove operating device communication e.g.: LiYY 3x0.75 mm² MZ-Home Clust-Air module CAM17 in the ventilation zone iV14-MaxAir ventilation device | Installation instructions...
  • Page 21 Cable type LiYY, 3-wire, Ventilation wire cross-section 0.75 mm², length devices max. 33 m Operated in pairs Control device: Terminal Switching power Pure: Control module blocks supply device sMove: Control device MZ-Home: Clust-Air module iV14-MaxAir ventilation device | Installation instructions...
  • Page 22: Installing The Wall Sleeve

    ► Cut the wall sleeve to the determined dimension X + a protrusion of Y on the exterior wall. Be careful not to cut away the cut-out for the fan connecting cable and the fixing elements. ► File the edges. iV14-MaxAir ventilation device | Installation instructions...
  • Page 23 • Do not remove the thread locks of the fixing elements until the inner cover is attached. ► Align the two lateral fastening elements of the wall sleeve horizontally. iV14-MaxAir ventilation device | Installation instructions...
  • Page 24 ► Cut out the 2K polyurethane foam and the potrud- ing mounting wedges flushing it to the inside and outside wall. Do not damage the connection cable on the inside wall. The wall sleeve is installed.  iV14-MaxAir ventilation device | Installation instructions...
  • Page 25: Installing The Ventilation Device's External Termination

    The cut-out in the circumferential end-stop tape is placed in the lower area of the wall sleeve. ► Break the pre-punched ring out of the base plate. iV14-MaxAir ventilation device | Installation instructions...
  • Page 26 These are not included in the scope of supply, they are available as an option. iV14-MaxAir ventilation device | Installation instructions...
  • Page 27 ► Place the cover onto the base plate from the top. ► Slide the cover downwards as far as the stop. The guides on the cover hook in behind the base plate. The Flex weather protection hood is installed.  iV14-MaxAir ventilation device | Installation instructions...
  • Page 28: Inserting The Thermal Accumulator Insert

    ► Insert the inVENTron from the interior into the wall sleeve so that you can reach the BUS plug Slim connection. The narrow Slim guiding vane [16 mm] is aligned towards the interior. The thermal accumulator insert has been inserted.  iV14-MaxAir ventilation device | Installation instructions...
  • Page 29: Electrical Connection Of The Reversible Fan

    INSTALLATION AND ASSEMBLY Electrical connection of the reversible fan The function of the iV14-MaxAir ventilation system requires the simultaneous operation of two iV14-MaxAir ventilation devices in push-pull mode. This section therefore describes the connection of a pair of devices, not a single device.
  • Page 30 5 Clamping screws on the controller 2 Plug-in connector on the fan cable plug-in connector 3 Plug-in connector on the controller cable 6 Clamping screws on the fan plug-in 4 Fan BUS [to controller] connector iV14-MaxAir ventilation device | Installation instructions...
  • Page 31: Check Function And Complete Fan Installation

    ► Make sure that all reversible fans rotate in the direction appropriate to their connections. Start direction extract air mode: Start direction supply air mode: Direction of fan clockwise Direction of fan counter clockwise inVENTron is connected and installed.  iV14-MaxAir ventilation device | Installation instructions...
  • Page 32: Installing The Inner Cover

    The position arrow on the base plate points  upwards. ► Screw the inner cover base plate to the wall sleeve's fixing elements using a hex key. iV14-MaxAir ventilation device | Installation instructions...
  • Page 33 4 x CLICK bottom right. ► Press the locking lugs inwards on the spacers. ► Slide the inner cover panel onto the spacers. All spacers noticeably snap in.  The inner cover panel is fitted.  iV14-MaxAir ventilation device | Installation instructions...
  • Page 34: Technical Data

    Sensitivity of the air flow at ± 20 Pa (EN 13141-8) Electrical protection area Outside protection areas 0 – 2 (in accordance with VDE 0100) Automatic by reversing operation Frost protection (down to -20 °C) Conformity iV14-MaxAir ventilation device | Installation instructions...
  • Page 35: Iv14-Maxair Energy Label According To Erp Directive, Regulation 1254/2014

    TECHNICAL DATA iV14-MaxAir energy label according to ErP Directive, Regulation 1254/2014 On the energy label you will find the following information from the product data sheet: • Energy efficiency class (SEC class) • Sound power level L • Maximum air flow (supply air)
  • Page 36: Specifications According To Erp Directive, Regulation 1254/2014

    TECHNICAL DATA Specifications according to ErP Directive, Regulation 1254/2014 iV14-MaxAir ventilation device, demand-controlled: iV14-MaxAir product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014 Description Values Supplier inVENTer GmbH iV14-MaxAir Model identifier iV14-MaxAir Corner iV14-MaxAir Nordic Cold -88.481...
  • Page 37 TECHNICAL DATA iV14-MaxAir ventilation device, manually controlled: iV14-MaxAir product data sheet according to EU Ordinance 1254/2014 dated 11 July 2014 Description Values Supplier inVENTer GmbH iV14-MaxAir Model identifier iV14-MaxAir Corner iV14-MaxAir Nordic Cold -82.817 SEC class / Specific Energy Average -39.977...
  • Page 38: Scope Of Supply

    Flair V-233x233 inner cover, white, incl. sound insulation SDE 1505-0037 Special variant: consisting of aluminium, with increased salt resistance Article numbers of any external termination variants in the separate installation instructions of the respective external termination. iV14-MaxAir ventilation device | Installation instructions...
  • Page 39: Troubleshooting

    Check the connector plug on the control- Supply air is cold ler. The connector plug must be sitting firmly in the connector housing. The controller is operating Select heat recovery mode on the in unidirectional ventilation controller. mode. iV14-MaxAir ventilation device | Installation instructions...
  • Page 40: Guarantee And Warranty

    To order components for your ventilation device, contact your nearest distributor or our service staff. Technical customer service For technical support contact our service staff: +49 (0) 36427 211-0 +49 (0) 36427 211-113 info@inventer.de http://www.inventer.eu iV14-MaxAir ventilation device | Installation instructions...
  • Page 41 GUARANTEE AND WARRANTY NOTES iV14-MaxAir ventilation device | Installation instructions...
  • Page 42 inVENTer GmbH Ortsstraße 4a D-07751 Löberschütz Germany www.inventer.eu Subject to modifications. We accept no liability for printing errors. Item number: 5001-0044 Version: 2.0 – 06/2022...