6. System Set-Up

6.1 Operating Instructions

PLEASE READ CAREFULLY BEFORE STARTING
WARNINGS:
1. The tube between the hydrogen pressure regulator and the fuel cell gas input is required to
be less than 30cm. The inner diameter of the hydrogen supply tube is required to be more
than 2mm. The input pressure to the stack is required to be 0.45-0.55Bar.
2. Disconnect the hydrogen tube from the hydrogen input immediately after the fuel cell stack is
shut down. Since hydrogen gas can leak into the fuel cell and destroy the stack.
3. Make sure the dry Hydrogen gas to be used must be
4. Do not vibrate the stack when it is in operation.
5. Keep the stack in ventilation when it is in operation.
99.995% purity.
Step 1: Use the tube to connect
the hydrogen supply (0.45-0.55
Bar) to the fuel cell hyrogen
input port.
Warning: The tube between the hydrogen pressure
regulator and the fuel cell gas input is required to
be less than 30cm.
Warning: before connecting the pin let the
hydrogen flow through the whole stack.
13
Step 2: To obtain higher
efficiency, you can connect a
pin to the H2 gas output.