8) After the water has completely drained out, plug in the ice dispenser or connect
the power source. When the 7-segment display on the controller board turns on,
press DOWN on the controller board for 3 seconds to start the flush mode. (See the
controller board service manual for further details.)
9) When the flush mode has started, pour the cleaning solution prepared in 1) carefully
into the water tank within 60 seconds before the pump motor starts. Do not splash or
spill the solution onto the other parts.
10) Allow the liquid to circulate for 30 minutes. Push the reset switch to open the water
pan. Unplug the ice dispenser or disconnect the power source when the water pan
has fully opened. Wait until the liquid has completely drained out.
11) Open the water supply tap, and repeat the above step 8), then step 10). Plug in the
ice dispenser.
12) Repeat the above step 11) at least three times to rinse thoroughly.
The cleaner must be completely flushed from the water circuit, or damage
could occur to the plastic parts.
SANITIZING INSTRUCTIONS
Note: Sanitizing should always be completed after cleaning or alternately as an
individual procedure if conditions exist to make it necessary.
13) Use a suitable container to dilute 44 ml of 5.25% sodium hypochlorite solution with
11.4 lit. of water.
* Alternatively use the Hoshizaki recommended sanitizer as directed by the relevant
instructions.
14) Close the water supply tap. Plug in the ice dispenser or connect the power source.
When the 7-segment display on the controller board turns on, press DOWN on the
controller board for 3 seconds to start the flush mode.
15) When the flush mode has started, pour the cleaning solution prepared in 13)
carefully into the water tank within 60 seconds before the pump motor starts. Do not
splash or spill the solution onto the other parts.
16) Circulate the sanitizing solution for 15 minutes. Push the reset switch to open the
water pan. Unplug the ice dispenser or disconnect the power source when the water
pan has fully opened. Wait until the sanitizing solution has completely drained out.