Hoshizaki DIM-30DE-2 Service Manual page 26

Cube ice dispenser
Hide thumbs Also See for DIM-30DE-2:
Table of Contents

Advertisement

Maintenance Mode Descriptions
No
Basic
10 Defrosting water supply
11 Defrosting water supply
Water supply
12 Icemaking water supply
13 Water temp
14 Full / partial drain flush
Item
1 Defrost completion temp Temperature to complete defrost cycle (detected
2 Integrated constant 1
(temp)
3 Integrated constant 2
(time)
4 Ambient temp correction
operating temp for
integrated value
5 Ambient temp correction
rate for integrated value
6 Freeze backup timer
time, water temp less
than 13°C
time, water temp 13°C or
more
time, normal
measurement correction
value
selection
by cube control thermistor).
Target integrated value inside controller board is
determined by constants 1 and 2. Temperature
in freeze cycle is integrated, and freeze cycle
continues until target integrated value is
reached. Basically, the smaller constant 1 gets,
the bigger integrated value and the smaller
dimple diameter become.
Target integrated value inside controller board is
determined by constants 1 and 2. Time in freeze
cycle is integrated, and freeze cycle continues
until target integrated value is reached.
Basically, the smaller constant 2 gets, the
smaller integrated value and the bigger dimple
diameter become.
Upper temperature limit to trip control to ensure
minimum dimple size in low temp conditions like
at 1°C / wt 5°C.
Percentage of integrated value in low temp
conditions against target integrated value
to ensure minimum dimple size in low temp
conditions like at 1°C / wt 5°C based on
integrated value inside controller board
determined by constants 1 and 2.
Timer setting to forcibly complete freeze cycle
if cube control thermistor cannot sense freeze
completion temp.
Time to supply defrosting water to melt ice on
water pan at water supply temp less than 13°C.
Adjustable between 1 and 99 sec. When set to
"99", defrosting water keeps running until cube
control thermistor senses defrost completion
temp.
Time to supply defrosting water to melt ice on
water pan at water supply temp of 13°C or more.
Adjustable between 1 and 99 sec. When set to
"99", defrosting water keeps running until cube
control thermistor senses defrost completion
temp.
Time to supply icemaking water depending on
partial or full drain flush.
Setting to correct difference between water
temp measured by cube control thermistor and
actual water supply temp.
Selection between full and partial drain flush
of icemaking water tank in case of cloudy
ice production even after hard water control.
Icemaking water supply time and water tank
overflow pipe direction need to be changed.
22
Description

Advertisement

Table of Contents
loading

Table of Contents