Needle Bar Height - Singer One Plus Service Manual

Hide thumbs Also See for One Plus:
Table of Contents

Advertisement

Service Manual

4. Needle bar height

Note: Make this checking before checking "Needle timing to shuttle" and
"Feed-dog timing (vertical motion)". Use needle Singer 90/14.
Checking:
1. Select straight stitch at center needle position.
2. Remove presser foot and needle plate, and then remove bobbin case.
3. Replace needle with special needle gauge (L=28.5 mm).
4. Lower the needle gauge to its lowest position by turning hand wheel by hand.
Check to see if the bottom of the needle gauge aligns with shuttle race pushing
the needle lightly as shown by arrow mark.
Highest position of
Needle
Shuttle race
Adjustment:
1. Remove face cover.
2. Loosen screw (A) of needle bar clamp using hex screw driver
and adjust the height of needle bar.
Needle gauge L = 29 mm
Needle position
at center
A
Original issue
Oct.2012
Page 12/41
Model
One Plus

Advertisement

Table of Contents
loading

Table of Contents