Motorline professional MC62 User's And Installer's Manual

Motorline professional MC62 User's And Installer's Manual

Advertisement

Quick Links

EN
MC62
MC62
USER'S AND INSTALLER'S MANUAL
v1.5
REV. 02/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC62 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Motorline professional MC62

  • Page 1 MC62 MC62 USER’S AND INSTALLER’S MANUAL v1.5 REV. 02/2022...
  • Page 2: Table Of Contents

    00. CONTENT 00. CONTENT INDEX INDEX 01. SAFETY INSTRUCTIONS 07. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS / TECHNICIANS 02. CONTROL BOARD 08. CONNECTIONS SCHEME CHARACTERISTICS CONNECTIONS MAP RECOMMENDATIONS PRIOR TO PROGRAMMING 03. INSTALLATION BASE INSTALLATION PROCESS REMOTE CONTROLS FUNCTIONS FUNCTIONS MENU "P" FUNCTIONS MENU "E"...
  • Page 3: Safety Instructions

    01. SAFETY INSTRUCTIONS 01. SAFETY INSTRUCTIONS ATTENTION: GENERAL WARNINGS • This manual contains very important safety and usage information. This product is certified in accordance with European very important. Read all instructions carefully before beginning Community (EC) safety standards. the installation/usage procedures and keep this manual in a safe place that it can be consulted whenever necessary.
  • Page 4 01. SAFETY INSTRUCTIONS 01. SAFETY INSTRUCTIONS • Children shouldn’t play with the product or opening devices from the ground or other level of access, the minimum safety to avoid the motorized door or gate from being triggered • and health requirements for the use of work equipment workers involuntarily.
  • Page 5 01. SAFETY INSTRUCTIONS 02. CONTROL BOARD CHARACTERISTICS The MC62 is a control board with built-in radio control system, developed for the in in motion, and do not create strength to the gate movement. automation of 24V swing gates. • Do not perform any operation on mechanical elements or hinges if the product is in motion.
  • Page 6: Control Board

    02. CONTROL BOARD 03. INSTALLATION CHARACTERISTICS BASE INSTALLATION PROCESS 01 • NO input for complete maneuver button The installation process assumes that the gate already has mechanical or 02 • Common electrical limit switches installed. For more information read the motor's manual 01 •...
  • Page 7: Remote Controls 7A

    03. INSTALLATION 03. INSTALLATION REMOTE CONTROLS FUNCTIONS Remote controls programming for total opening. Remote controls programming for pedestrian opening. We can only go into programming with the gate electrically stumbled. • PROGRAMMING REMOTE CONTROLS • ERASE REMOTE CONTROLS The functions of the control board are divided into 2 areas: •...
  • Page 8: Functions Menu "P" 8A

    03. INSTALLATION 03. INSTALLATION FUNCTIONS MENU "P" FUNCTIONS MENU "E" MAX. MIN. FACTORY MAX. MIN. FACTORY MENU FUNCTION STATE PAGE MENU FUNCTION STATE PAGE PROGRAMMABLE VALUE PROGRAMMABLE VALUE Desactivates human present Manual Programming Activates human present Course Programming 1 motor Disables push buttons mode 2 motors Activates push buttons mode...
  • Page 9: Programming "P

    04. PROGRAMMING "P" 04. PROGRAMMING "P" COURSE PROGRAMMING DECELERATION TIME ADJUSTMENT This menu allows to set the deceleration time of each leaf at opening and closing. Course Manual Programming Number of Motors This menu allows you to manually set the course of Allows you to define the number of motors connected the leaf/leaves.
  • Page 10: P3-Pedestrian Course Time 10A

    04. PROGRAMMING "P" 04. PROGRAMMING "P" FORCE AND SENSIVITY ADJUSTMENT PAUSE TIME AND GATES DELAY 01 • Press MENU for 2 sec. until it appears 01 • Press MENU for 2 sec. until it appears 02 • Use UP until appears 02 •...
  • Page 11: P6-Photocells 2 Programming 11A

    04. PROGRAMMING "P" 04. PROGRAMMING "P" PHOTOCELLS 2 PROGRAMMING OPERATING LOGIC 01 • Press MENU for 2 sec. until it appears Allows to program le security behavior (photocell 2). 02 • Use UP until appears 03 • Press Menu will appear 04 •...
  • Page 12: Programming "E

    04. PROGRAMMING "P" 05. PROGRAMMING "E" REMOTE PROGRAMMING SOFT START 01 • Press MENU for 2 sec. until it appears 00 human presence 02 • Use UP until appears 01 function activated 03 • Press Menu will appear This menu allows activate/disable soft start. 04 •...
  • Page 13: E4-Course Time Adjustment

    05. PROGRAMMING "E" 05. PROGRAMMING "E" FOLLOW ME BRAKE/LOCK/PUSH 00 function disabled Allows to program gate behavior 01 function activated after opening 02 function activated on opening 00 (disables 00 (active lock on 00 (disable opening 00 (disables closing 00 (disables motor Allows you to activate the Follow me option.
  • Page 14: E7-Manuevers Counter

    05. PROGRAMMING "E" 05. PROGRAMMING "E" MANUEVERS COUNTER RESET - RESET FACTORY VALUES This menu allows you to view the number of maneuvers were performed by the control board. (complete maneuver means opening and closing). When resetting, all factory values will be reset. Resetting the control board does not clear the maneuver count.
  • Page 15: Display

    06. DISPLAY DISPLAY INDICATIONS MENU DESCRIPTION MENU DESCRIPTION In the stopped position, fully opened All remote controls erased In the stopped position, intermediate position Remote control triggered from the indicated position In the stopped position, fully closed Obstructed photocell Full opening button pressed Obstructed photocell Pedestrian opening button pressed In pause time...
  • Page 16: Troubleshooting

    07. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS / TECHNICIANS Anomaly Anomaly Procedure Procedure Behavior Behavior Procedure II Procedure II Discovering the origin of the problem Discovering the origin of the problem • Make sure you • Make sure you 1 • Open control box and check if 1 •...
  • Page 17: Connections Scheme Connections Map

    08. CONNECTIONS SCHEME CONNECTIONS MAP...

Table of Contents