10-2 Module Specifications - Mitsubishi STERAPORE 5600 FF Series Instruction Manual

Table of Contents

Advertisement

10-2 Module Specifications

Product specifications for modules are given below.
Specifications indicated in this manual may be subject to change without notice.
Please select a hoist and other equipment for lifting modules while taking the weight of the module, chains
and connecting pipes into account. If the product has been operated at a trans membrane pressure
significantly beyond the range specified in this manual, it is possible that an extreme amount of clogging has
occurred, which may cause the product to exceed its wet weight.
Item
Module model number
Model no.
No. of elements
Element
Dimensions (D×W×H)
Nominal membrane surface area
Module membrane surface area
Dimensions
Weight
No. of permeate adapters
required
Connection to treated water
(JIS10K)
Guide pipe specifications
Diffuser
Diffuser
part
Connection (JIS10K)
Minimum aeration rate
Maximum aeration rate
Diffuser
air
Standard aeration rate
Diffuser pressure loss (Maximum)
Minimum water depth
Standard
center-to-center
distance for modules
Filtration mode
Normal trans membrane pressure
Normal temperature
pH range of raw water
Oil content range of raw water
pH range for cleaning
MLSS range
(Membrane Tank)
Design filtration flow
Other
*1 Reference lifting weight when wet. The actual lifting weight differs according to the operating conditions and the
amount of adhered sludge.
*2 Design filtration flow is calculated based on the assumption that flux is between 0.2 and 0.8 m
according to the raw water conditions, operating temperature, etc.
Standard accessories
 Water collection adapter
(permeate adapter)
STERAPORE 5600 Series (FF) Instruction Manual
Table 10-2 Module Specifications List (Element used: 56E0040SA)
Unit
pcs.
mm
2
m
2
m
Depth
mm
Width
mm
Height
mm
Dry
kg
1
Lifting
kg
pairs
Model number
3
Nm
/min
3
Nm
/min
3
Nm
/min
kPa
m
Depthwise
Widthwise
mg/L
3
m
/(day・
2
module)
Accessories not included
 Guide rail
 Chains and shackles
 Chain blocks and cranes
 Slings and lifting beams
56M0400FF 56M0800FF
10
20
400
800
1,524
1,524
940
1,390
2,798
2,798
400
600
500 to 1,000
800 to 1,800
20
40
65A Flange
65A Flange
× 2
× 2
50A
50A
FB-10W
FB-20W
80A Flange 80A Flange
0.8
1.5
1.7
3.1
1.5
2.7
1.1
1.1
3.0
3.0
2.2 m or greater (The wall-to-c enter distance for modules adjacent to
walls must be 1.1 m or greater.)
Secure a sufficient distance for tying in pipes or lifting the module.
Submerged suction filtration (out-in filtration)
Initial trans membrane pressure: -15 kPa or above
Normal hexane extracts 150 mg/L or below (excluding mineral oils)
Recommended range of application: 5,000 to 10,000
(min: 3,000; max: 15,000)
80 to 320
160 to 640
Silicon antifoaming agent may not be used.
Chapter 10 Specifications
Specifications
56M1200FF 56M1600FF
56E0040SA
30
40
30 × 1,250 × 2,000
40
1200
1600
1,524
1,524
1,870
2,320
2,798
2,798
800
1,000
1,100 to 2,600 1,400 to 3,400 2,100 to 5,100
60
80
65A Flange
65A Flange
× 2
× 2
80A
80A
FB-30W
FB-40W
80A Flange
80A Flange
2.2
2.9
4.5
5.9
3.8
5.0
1.1
1.1
3.0
3.0
5 to 40
5 to 9
1.0 to 11.0
240 to 960
320 to 1,280
 Filtered water hose and pipes, air
hose and pipes
 Protective sheets and covers
56M2400FF
60
2400
1,524
3,416
2,798
1,550
120
65A Flange
× 4
80A
FB-60W
80A Flange × 2
4.4
9.0
7.7
1.1
3.0
480 to 1,920
3
2
•d). It differs
/(m
58/59

Hide quick links:

Advertisement

Table of Contents
loading