Check that the modules are level.
Install modules in a location with horizontality of 3 mm/1,000 mm or less. Placing modules on a
surface which has a greater slope may result in uneven aeration and inadequate membrane
scouring and cause membrane clogging.
When installing several modules, ensure that the difference in height between the tops of the
modules is no more than 6 mm. If the difference is higher than this, diffusion between the modules
will not be uniform.
C AUT IO N
Take care as modified tanks may be sloped. Make sure that diffusers in the same group are
installed at the same height.
8.
Connect pipes to modules.
Connect pipes (suction and diffuser pipes) to modules after installation preparation, confirmation
before installation, and steps 1 to 6 have been completed.
RE F ER E NC E
 Perform conditioning after installing the modules. (See p.40 "6-1 Commissioning")
5-1-6 Element Replacement Procedure
Replace elements in accordance with the separate "Element Replacement Manual" after confirming
which membrane module model you are using.
STERAPORE 5600 Series (FF) Instruction Manual
Figure 5-6 Example of Module Installation
Chapter 5 Transport and Installation
37/59