Chapter 10 Specifications; 10-1 Element Specifications - Mitsubishi STERAPORE 5600 FF Series Instruction Manual

Table of Contents

Advertisement

Chapter 10 Specifications

10-1 Element Specifications

Product specifications for membrane elements are given below.
Specifications indicated in this manual may be subject to change without notice.
Item
Element model number
Nominal membrane surface area
Direction of hollow fiber membrane
Hollow fiber membrane
Potting resin
Reinforcing resin
Water collection pipe
Support pipe
Nominal pore size
Outer diameter of hollow fiber
membrane
Element dimensions (D×W×H)
Dry weight
Connection
Design filtration flow
Filtration mode
Normal trans membrane
pressure
Normal temperature
pH range of raw water
Oil content range of raw
water
pH range for cleaning
MLSS range
(Membrane Tank)
Other
*
Design filtration flow is calculated based on the assumption that flux is between 0.2 and 0.8 m
according to the raw water conditions, operating temperature, etc.
STERAPORE 5600 Series (FF) Instruction Manual
Table 10-1 Element Specifications
Unit
2
m
μm
mm
mm
kg
mm
3
m
/(day・
element)
mg/L
Specifications
56E0040SA
40
Vertical
PVDF (polyvinylidene fluoride)
Polyurethane resin
Polyurethane resin
ABS Resin
SUS304
0.05
1.65
30 × 1,250 × 2,000
Approx. 15
φ24 × 2 locations
Upper
element permeate
header/lateral
5 to 20
Submerged suction filtration (out-in filtration)
Initial trans membrane pressure: -15 kPa or above
5 to 40
5 to 9
Normal hexane extracts 150 mg/L or below
(excluding mineral oils)
1 to 11
Recommended range of application:
5,000 to 10,000 (min: 3,000, max: 15,000)
Silicon antifoaming agents may not be used.
Chapter 10 Specifications
3
2
•d). It differs
/(m
57/59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents