PST (post fader) button: Selects the signal of the
point located before the pan of the input signal path.
For AUX send, MTR bus and PGM, the signal after the
master fader is selected.
PEAK HOLD button
Selects the method used to display the peak hold level
of the input signals.
MAN (manual) button: Touch this button to always
display the maximum level of the input signal
(peakhold status). Touch this button again to cancel the
display of the peakhold status.
AUTO button: Touch this button to display the peak
level of the input signal for three seconds, and the hold
display is automatically reset.
3 MTR BUS MODE section
Touch the button to display SURROUND. When
SURROUND is displayed, the MTR bus is set to
surround mode. When the display is off, the MTR bus
is set to mono/stereo mode.
4 TOUCH SENSOR section
Sets the sensitivity of the fader touch sensor.
SENSITIVITY display: Displays the sensitivity as
steps of 0 to 15. The maximum sensitivity is 15.
v/V buttons: Increase or decrease the sensitivity.
KEEP button: Touch this button to store the
sensitivity on the SENSITIVITY display window in
the current title. At the same time, data in the work
area is also stored in the current title.
5 TOUCH PANEL section
Calibrates the touch panel.
When the cursor does not move correctly, calibration
of the touch panel is required.
Touch the button to open the calibration window.
To calibrate the touch panel, proceed as follows:
1
Turn off the power and connect a mouse to the
MOUSE connector on the rear panel. Then turn on
the power again.
2
Select the CALIBRATE button on the TOUCH
PANEL section.
A dialog box appears.
3
Select [YES] on the dialog box.
The calibration window appears.
4
Touch the CALIBRATE button on the window.
Perform the following operations, step 5 to step 7,
according to the blue arrow indicated on the
calibration window.
5
Touch the left top of the window according to the
blue arrow indication.
The blue arrow indication turns red. By touching
the left top again, the arrow turns blue and points
to the right bottom.
Note
The arrow indicates the corner to be touched. Be
careful not to touch the arrow itself. If you touch
the arrow accidentally, start the calibration
operation again from step 1.
6
Touch the right bottom on the window according
to the blue arrow indicator.
Touching the arrow at the first time causes the
blue arrow to turn red. Touching the red arrow
causes a circle mark to appear at a point a little to
the right of the center.
Note
Be careful not to touch the arrow.
7
Touch the circle mark on the window.
8
Touch the EXIT button to terminate the
calibration.
The calibration of the touch panel is terminated.
Note
If you fail to calibrate the touch panel, you won't be
able to operate the touch panel. If you fail, open the
CALIBRATION panel using the mouse connected to
the MOUSE connector again, then perform operations
of step 5 to 8 again.
6 DIM LEVEL section
Adjusts the dimmer level of the monitor signals.
v/V buttons: Increase or decrease the dimmer level of
the CR MON (control room monitors) or STUDIO LS
(studio monitors). The adjusted values are displayed
on the display windows.
KEEP button: Touch this button to store the dimmer
level displayed on the window in the current title. At
the same time, data in the work area is also stored in
the current title.