1. Specifications 1.1 Performance data Dura V UNIT DURA-V10 DURA-V15 UNIT DURA-V20 Advised Pool volume* Advised Pool volume* Operating air temperature °C -10 ~ 40 Operating air temperature °C -10 ~ 40 Min operating water temperature °C 0 ~ 40 Min operating water temperature °C 0 ~ 40...
Page 4
1.2 Performance data Dura Vi UNIT DURA-V11i DURA-V15i UNIT DURA-V20i Advised Pool volume** 30 - 60 40 - 75 Advised Pool volume** 50 - 95 Operating air temperature °C -10 ~ 40 Operating air temperature °C -10 ~ 40 Min operating water temperature °C 0 ~ 40 Min operating water temperature...
2. Preface 4. Preparing the heat pump for use In order to provide our customers with a high quality and reliability, this product has been made to strict production standards. This manual includes all the necessary information about installation, 4.1 Typical set-up debugging, discharging and maintenance.
4.3 Installation of the tubing Connect the electrical wires using the following steps Step 1: Remove display. Step 2: Unscrew blue front housing. The factory provides the water connecting kit. Other parts, including a contingent by-pass are to be provided by the user or installer.
5. Be aware of 5.3 Unobstructed space A free area around the heat pump has to be kept clear from any object to get fresh air across the 5.1 Heat loss evaporator. Do not obstruct the fan. The pool heat pump is installed within 7.5 meters of the pool. The longer the distance from the blow out: pool, the greater the heat loss from the tubing.
6.2 Types of display interfaces in the heat pump 6.3 General interface 4 types of interfaces can be found in the heat pump. Set: Highlights when the heat pump is unlocked. 1: General interface. Meaning the heat pump desired temperature or parameters can be changed.
6.4 Parameter interface Following general interface is shown when the water temperature is below 0°C(min water temperature to start the heat pump). Parameters can be set by a qualifi ed person in order to make the heat pump more effi cient depending on the specifi c conditions of the swimming pool.
6.6 Error parameter interface A complete list of errors can be found in the error parameter interface. Number of error in the heat pump: Number of error. The following can be found: Noticifaction of Error. A temperature sensor error is active in the heat pump. Notifi cation of error Error notifi cation name: Name of error in the heat pump.
7. Wiring diagrams 7.2 Wire control interface diagram Dura Vi 7.1 Wire control interface diagram Dura V Ferrite bead 1 CONTROL BOARD Water in EVAP Pres1 Sudi Evap Cond Pres2 Flow Flow Water out Disp Display Valve Rs485 Heat blu -n Electronic Expansion valve...
If you need service or information or if you have a problem, please contact your local dealer. If needed they will contact the manufacturer to solve your problem. They are gladly willing to assist you! You can fi nd more information at www.duratech.be...
12. Warranty LIMITED WARRANTY We warrant all parts to be free from manufacturing defects in materials and workmanship for a period of THREE years from the date of retail purchase. This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites.
Page 24
HEAT Accessories VISION Specials Declaraction of Conformity Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be Contact details Propulsion Systems bv Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 www.duratech.be...
Need help?
Do you have a question about the HEAT DURA-V10 and is the answer not in the manual?
Questions and answers