Advertisement

Manual
DURA-V10
DURA-V15
DURA-V20
DURA-V11i
DURA-V15i
DURA-V20i
DURA-V24i
V / Vi

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DURA V Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Duratech DURA V Series

  • Page 1 Manual DURA-V10 DURA-V15 DURA-V20 DURA-V11i DURA-V15i DURA-V20i DURA-V24i V / Vi...
  • Page 2: Table Of Contents

    Table of contents Box contents........................Dimensions......................... 1. Specifications........................1.1. Performance data Dura V................. 1.2. Performance data Dura Vi................ 2. Preface........................... 3. Safety information......................4. Preparing the heat pump for use..................4.1. Typical set-up.................... 4.2. Installation of a check valve..............4.3. Installation of the tubing................4.4.
  • Page 3: Box Contents

    Box content Heat pump Dura V or Vi Connection clamps Wintercover Drain pipe(Condens Flux) Manual Dimensions DURA-V10 / DURA-V15 / Dura-V20 723mm 776mm DURA-V11i / DURA-V15i / Dura-V20i / DURA-V24i 723mm 776mm...
  • Page 4: Specifications

    1. Specifications 1.1 Performance data Dura V UNIT DURA-V10 DURA-V15 Advised Pool volume* Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 10,6 36169 51182 Consumed power 2,05 Air 15°C / Water 26°C / Humidity 70% Heating Capacity 10,5 25591...
  • Page 5 UNIT DURA-V20 Advised Pool volume* Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 68243 Consumed power 2,85 Air 15°C / Water 26°C / Humidity 70% Heating Capacity 13,4 45723 Consumed power Power supply 230V / 50Hz / 1 Phase Electronic Controller...
  • Page 6: Performance Data Dura Vi

    1.2 Performance data Dura Vi UNIT DURA-V11i DURA-V15i Advised Pool volume** 30 - 60 40 - 75 Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 3,4 - 11,4 4,1 - 15,1 11601 - 38898 13990 - 51523 Consumed power...
  • Page 7 UNIT DURA-V20i DURA-V24i Advised Pool volume** 50 - 95 65 - 120 Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 5,6 - 20,0 6,5 - 23,6 19108 - 68243 22179 - 80527 Consumed power 0,41 - 2,82 0,43 - 3,37...
  • Page 8: Preface

    2. Preface In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
  • Page 9: Preparing The Heat Pump For Use

    4. Preparing the heat pump for use 4.1 Typical set-up The factory only provides the heat pump. Other parts, including a contingent by-pass are to be provided by the user or installer. The heat pump should be located maximum 7,5m(1) away from the swimming pool. The longer the distance from the pool, the greater the heat loss from the piping.
  • Page 10: Installation Of The Tubing

    4.3 Installation of the tubing The factory provides the water connecting kit. Other parts, including a contingent by-pass are to be provided by the user or installer. The heat pump should be located maximum 7,5m away from the swimming pool. The longer the distance from the pool, the greater the heat loss from the piping.
  • Page 11 Connect the electrical wires using the following steps Step 1: Remove display. Step 2: Unscrew blue front housing. Step 3: Snap off blue front housing Step 4: Remove flow sensor Please turn off filter pump. Flow must be stoped before disconnecting flow sensor. Drain the water out of the condensor to prevent water loss.
  • Page 12: Be Aware Of

    5. Be aware of 5.1 Heat loss The pool heat pump is installed within 7.5 meters of the pool. The longer the distance from the pool, the greater the heat loss from the tubing. Therefore, the heat loss is minimal for runs of up to 7,5 meters(7,5 meters to and from the pump = 15 meters total), unless the ground is wet or the water table is high.
  • Page 13: Unobstructed Space

    5.3 Unobstructed space A free area around the heat pump has to be kept clear from any object to get fresh air across the evaporator. Do not obstruct the fan. blow out: 3000mm inlet air: inlet air: 1500mm 1500mm inlet air: connection 1500mm area:1000mm...
  • Page 14: General Display Interface

    6.2 General display interface Set: Highlights when the heat pump is unlocked. Meaning the heat pump desired temperature or parameters can be changed. Low air temperature: Set temperature: The heat pump stops Shows the desired temperature of the swimming working and will restart pool.
  • Page 15: Settings/ Parameter Display Interface

    6.3 Setting/parameter display interface An installed heat pump can work more efficient according to the local pool system, environment, distance from pool and other pool equipment. A qualified person will set these parameters in order to get as much as possible performance and reliability. Parameter name: Name of parameter.
  • Page 16: Alarm Display Interface

    6.4 Alarm display interface An intelligent alarm program is built into the heat pump. When an alarm occurs the heat pump will try to solve the issue by looking at several parameters, restarting components and bypassing electronics. 2 type of alarms can be found: 1) PROGRAM ALARMS can be found in the general display interface and settings/ parameter interface.
  • Page 17: Error Display Interface

    6.5 Error display interface An error occurs when a program alarm can not be solved within the 24 hours alarm countdown or when 3 temperature alarms are active. Please contact your service centre or similarly qualified persons when an error is still active after deconnecting from electricity and restarting the heat pump.
  • Page 18: Parameter Code List

    6.6 Parameter code list...
  • Page 22: Alarm Code List

    6.7 Alarm code list...
  • Page 25: Error Code List

    6.8 Error code list...
  • Page 29: Wiring Diagrams

    7. Wiring diagrams 7.1 Wire control interface diagram Dura V...
  • Page 30: Wire Control Interface Diagram Dura

    7.2 Wire control interface diagram Dura Vi Ferrite bead 1 CONTROL BOARD Pres1 Sudi Cond Water in EVAP Evap Pres2 Flow Flow Water out Display Disp Valve Rs485 Heat blu -n Electronic Expansion valve 4way Ferrite bead 2 yel (l) blk (h) Drain Heater wht -n...
  • Page 31: Piping Diagram And Definition Dura V And Dura

    7.3 Piping diagram and definition Dura V and Dura Vi...
  • Page 32: Maintenance And Inspection

    If you need service or information or if you have a problem, please contact your local dealer. If needed they will contact the manufacturer to solve your problem. They are gladly willing to assist you! You can find more information at www.duratech.be...
  • Page 33: Warranty

    12. Warranty LIMITED WARRANTY We warrant all parts to be free from manufacturing defects in materials and workmanship for a period of THREE years from the date of retail purchase. This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites.
  • Page 36 Propulsion Systems bvba Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.duratech.be info@propulsionsystems.be We reserve the rights to change all or part of the contents of this document without prior notice...

Table of Contents