Table of contents Box contents........................Dimensions......................... 1. Specifications........................1.1. Performance data Dura V................. 1.2. Performance data Dura Vi................ 2. Preface........................... 3. Safety information......................4. Preparing the heat pump for use..................4.1. Typical set-up.................... 4.2. Installation of a check valve..............4.3. Installation of the tubing................4.4.
1. Specifications 1.1 Performance data Dura V UNIT DURA-V10 DURA-V15 Advised Pool volume* Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 10,6 36169 51182 Consumed power 2,05 Air 15°C / Water 26°C / Humidity 70% Heating Capacity 10,5 25591...
Page 5
UNIT DURA-V20 Advised Pool volume* Operating air temperature °C -10 ~ 40 Air 27°C / Water 26°C / Humidity 80% Heating Capacity 68243 Consumed power 2,85 Air 15°C / Water 26°C / Humidity 70% Heating Capacity 13,4 45723 Consumed power Power supply 230V / 50Hz / 1 Phase Electronic Controller...
2. Preface In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
4. Preparing the heat pump for use 4.1 Typical set-up The factory only provides the heat pump. Other parts, including a contingent by-pass are to be provided by the user or installer. The heat pump should be located maximum 7,5m(1) away from the swimming pool. The longer the distance from the pool, the greater the heat loss from the piping.
4.3 Installation of the tubing The factory provides the water connecting kit. Other parts, including a contingent by-pass are to be provided by the user or installer. The heat pump should be located maximum 7,5m away from the swimming pool. The longer the distance from the pool, the greater the heat loss from the piping.
Page 11
Connect the electrical wires using the following steps Step 1: Remove display. Step 2: Unscrew blue front housing. Step 3: Snap off blue front housing Step 4: Remove flow sensor Please turn off filter pump. Flow must be stoped before disconnecting flow sensor. Drain the water out of the condensor to prevent water loss.
5. Be aware of 5.1 Heat loss The pool heat pump is installed within 7.5 meters of the pool. The longer the distance from the pool, the greater the heat loss from the tubing. Therefore, the heat loss is minimal for runs of up to 7,5 meters(7,5 meters to and from the pump = 15 meters total), unless the ground is wet or the water table is high.
5.3 Unobstructed space A free area around the heat pump has to be kept clear from any object to get fresh air across the evaporator. Do not obstruct the fan. blow out: 3000mm inlet air: inlet air: 1500mm 1500mm inlet air: connection 1500mm area:1000mm...
6.2 General display interface Set: Highlights when the heat pump is unlocked. Meaning the heat pump desired temperature or parameters can be changed. Low air temperature: Set temperature: The heat pump stops Shows the desired temperature of the swimming working and will restart pool.
6.3 Setting/parameter display interface An installed heat pump can work more efficient according to the local pool system, environment, distance from pool and other pool equipment. A qualified person will set these parameters in order to get as much as possible performance and reliability. Parameter name: Name of parameter.
6.4 Alarm display interface An intelligent alarm program is built into the heat pump. When an alarm occurs the heat pump will try to solve the issue by looking at several parameters, restarting components and bypassing electronics. 2 type of alarms can be found: 1) PROGRAM ALARMS can be found in the general display interface and settings/ parameter interface.
6.5 Error display interface An error occurs when a program alarm can not be solved within the 24 hours alarm countdown or when 3 temperature alarms are active. Please contact your service centre or similarly qualified persons when an error is still active after deconnecting from electricity and restarting the heat pump.
If you need service or information or if you have a problem, please contact your local dealer. If needed they will contact the manufacturer to solve your problem. They are gladly willing to assist you! You can find more information at www.duratech.be...
12. Warranty LIMITED WARRANTY We warrant all parts to be free from manufacturing defects in materials and workmanship for a period of THREE years from the date of retail purchase. This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites.