INSTRUCTIONS FOR USE
GENERATORS
MODELS
SILENTSTAR
6000D M YN
6500D T YN
MU_02GE_SILENTSTAR_6000D_6500D_EN
Édition : 20190903

Advertisement

Table of Contents
loading

Summary of Contents for WORMS SILENTSTAR 6000D M YN

  • Page 1 INSTRUCTIONS FOR USE GENERATORS MODELS SILENTSTAR 6000D M YN 6500D T YN MU_02GE_SILENTSTAR_6000D_6500D_EN Édition : 20190903...
  • Page 2 Thank you for purchasing a Worms Entreprises generator. This manual covers operation and maintenance of the Worms Entreprises generators. All information in this publication is based on the latest production information available at the time of approval for printing. Pay special attention to statements preceded by the following words: Indicates an impending dangerous situation.
  • Page 3: Table Of Contents

    SUMMARY 1. SYMBOLS AND MEANINGS ............................PAGE 2. SAFETY PRECAUTIONS ............................. PAGE 3. SPECIFICATIONS ................................PAGE 4. CONTROL PANEL ................................PAGE 5. PRE-OPERATION CHECK ............................PAGE 6. OPERATING PROCEDURES ..........................PAGE 7. STOPPING THE GENERATOR ..........................PAGE 8. OIL SENSOR ..................................
  • Page 4: Symbols And Meanings

    1. SYMBOLS AND MEANINGS In accordance with the ISO standard, the specified symbols as shown in the following table are used for the products and this instruction manual. Read the operator’s instruction manual. Stay clear of the hot surface. Exhaust gas is poisonous. Do not operate in an unventilated room.
  • Page 5 ON (Switch Engine) Rated power (kW) ƒ r OFF (Switch Engine) Rated frequency (Hz) Maximum site altitude above H max Alternating current sea-level (m) Direct current Continuous power (kW) Plus : positive polarity Rated voltage (V) Maximum ambient tempera- T max Minus : negative polarity ture (°C) COS ϕ...
  • Page 6: Safety Precautions

    2. SAFETY PRECAUTIONS Do not operate the generator near gasoline or gaseous fuel because of the potential danger of explosion or fire. Do not fill the fuel tank with fuel while the engine is running. Do not smoke or use a naked flame near the fuel tank. Be careful not to spill fuel during refueling.
  • Page 7 Be extremely careful that all necessary electrical grounding procedures are followed during each and every use. Failure to do so can be fatal. Do not contact the generator to a commercial power line. Connection to a commercial power line may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for connecting to domestic circuit.
  • Page 8: Specifications

    3. SPECIFICATIONS SILENTSTAR SILENTSTAR 6000D M YN 6500D T YN LTP Power 230V (cos 5200 W 3600 W ϕ COP Power 230V (cos 4400 W 3600 W ϕ 5200 W / 6500 VA LTP Power 400V (cos =0,8) ϕ COP Power 400 V (cos =0,8) 4400 W / 5500 VA ϕ...
  • Page 9: Control Panel

    4. CONTROL PANEL Current leakage protection and circuit Single phase socket 230 V - 10/16 A breaker SCHUKO Voltmeter Single phase socket 230 V - 16 A CEE Single phase socket 230 V - 32 A - CEE Hourmeter or Three phase socket 400 V - 3P+T+N 16 A Frequencymeter Earth connection Emergency Stop...
  • Page 10: Pre-Operation Check

    5. PRE-OPERATION CHECK CHECK ENGINE OIL Before checking or refilling oil, be sure generator is located on stable and level surface with engine stopped. • Remove oil filler cap (a) and check the engine oil level. • If oil level is below the lower level line (c), refill with suitable oil (see table) to upper level line (b). Do not screw in the oil filler cap when checking oil level.
  • Page 11 CHECK ENGINE FUEL Do not remove the fuel tank cap while the engine is running. Do not refuel while smoking or near naked flame or other such potential fire hazards. Otherwise fire accident may occur. Check fuel level at fuel level gauge (standard with large fuel tanks). If fuel level is low, refill with Diesel. Be sure to use the fuel filter screen on the fuel filter neck before filling the tank.
  • Page 12 • Make sure you review each warning in order to prevent fire hazard. • Do not refill tank while engine is running or hot. • Be careful not to admit dust, dirt, water or other foreign objects into fuel. • Wipe off split fuel thoroughly before starting engine.
  • Page 13: Operating Procedures

    6. OPERATING PROCEDURES Check the oil level before each operations as outlined on page 9. Never change the accelerator position which is set at the factory. Before starting the generator, check the DIESEL hoses are air drained. 6.1. STARTING THE ENGINE NOTE All the information related to the display is written in the manual user book.
  • Page 14 6.3. USING ELECTRIC POWER AC APPLICATION This generator is thoroughly tested and adjusted in the factory. If the generator does not produce the specified voltage, consult your nearest Worms dealer or service shop. • Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.
  • Page 15: Stopping The Generator

    When the circuit breaker or no-fuse breaker turns off during operation, the generator is overloaded or the appliance is defective. Stop the generator immediately, check the appliance and/or generator for overloading or detect and have repaired as necessary by Worms dealer or service shop. 7. STOPPING THE GENERATOR Turn off the power switch of the electric equipment and unplug the cord from the receptacle of the generator.
  • Page 16: Oil Sensor

    10 and restart the engine. NOTE If the engine doesn’t start by usual, consult your nearest Worms Entreprises dealer or service shop. 9. WATTAGE INFORMATION Some appliances need a ‘‘surge’’ of energy when starting. This means that the amount...
  • Page 17: Maintenance Schedule

    AVR OPTION Voltage regulating ± 2 % ± 2 % VOLTAGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator, a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool.
  • Page 18: How To'' Maintenance

    NOTE • Maintenance operations require trained and qualified personel. • The maintenance schedule is given as a guide. Under severe conditions, the frequency of maintenance must be increased. • Initial oil change should be performed after first twenty (20) hours of use. Thereafter change oil every 100 hours.
  • Page 19 11.2. CLEANING AIR CLEANER A dirty air cleaner element will cause starting difficulty, power loss, engine malfunctions, and shorten engine life extremely. Always keep the air cleaner element clean. • URETHANE FOAM CLEANING: Work and clean the urethane foam with detergent. After cleaning, dry it.
  • Page 20: Preparation For Storage

    11.3. CONTROL OF THE BATTERY VOLTAGE BATTERY 12. PREPARATION FOR STORAGE The following procedures should be followed prior to storage of your generator for periods of 6 months or longer. • Drain fuel from fuel tank carefully by disconnecting the fuel line. Diesel left in the fuel tank will eventually deteriorate making engine-starting difficult.
  • Page 21: Troubleshooting

    When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or to generate electricity, contact your nearest Worms Entreprises dealer or service shop for further information or corrective procedures.
  • Page 24 MU_02GE_SILENTSTAR_6000D_6500D_EN Siège social / Head Offi ce Service SAV et Garantie After Sales and Waranty Service ZAC de Lamirault 39 rue de Lamirault, 77090 Collégien, FRANCE TEL. +33 (0) 1 64 76 29 80 TEL. +33 (0) 1 64 76 29 50 FAX +33 (0) 1 64 76 29 88 FAX +33 (0) 1 64 76 29 99...