BLOWER PERFORMANCE DATA - SINGLE/THREE PHASE
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
745
76
0.2
690
84
0.3
635
91
0.4
570
98
0.5
505
107
0.6
450
115
0.7
395
118
0.8
345
126
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
1,055
156
0.2
1,000
166
0.3
940
173
0.4
880
181
0.5
825
189
0.6
760
204
0.7
705
207
0.8
625
210
T1 HEATING SPEED
E.S.P.
CFM
WATTS
0.1
1,055
156
0.2
1,000
166
0.3
940
173
0.4
880
181
0.5
825
189
0.6
760
204
0.7
705
207
0.8
625
210
X = Heating Temperature Rise Not Recommended.
NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, exter-
nal static pressure should not exceed 0.5" w.c.
DP14GM3604041** - Rise Range: 25° - 55°
T2 HEATING SPEED
RISE
CFM
WATTS
41
1,115
206
45
1,075
215
48
1,030
221
54
985
233
X
940
234
X
895
242
X
845
248
X
785
252
DP14GM3606041** - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
X
1,115
206
X
1,075
215
X
1,030
221
X
985
233
X
940
234
X
895
242
X
845
248
X
785
252
DP14GM3608041/43** - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
X
1,115
206
X
1,075
215
X
1,030
221
X
985
233
X
940
234
X
895
242
X
845
248
X
785
252
*P14GM4206041** - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
44
1,380
298
46
1,320
312
49
1,270
318
52
1,220
327
56
1,160
336
X
1,115
342
X
1,060
347
X
1,000
361
*P14GM4208041** - Rise Range: 30° - 60°
T2 HEATING SPEED
RISE
CFM
WATTS
58
1,380
298
X
1,320
312
X
1,270
318
X
1,220
327
X
1,160
336
X
1,115
342
X
1,060
347
X
1,000
361
T3 HEATING SPEED
RISE
CFM
WATTS
28
1,265
285
29
1,230
290
30
1,175
300
31
1,140
303
33
1,100
311
34
1,055
319
36
1,010
326
39
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
41
1,265
285
43
1,230
290
45
1,175
300
47
1,140
303
49
1,100
311
52
1,055
319
55
1,010
326
59
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
55
1,265
285
57
1,230
290
60
1,175
300
X
1,140
303
X
1,100
311
X
1,055
319
X
1,010
326
X
960
335
T3 HEATING SPEED
RISE
CFM
WATTS
33
1,415
327
35
1,360
335
36
1,305
343
38
1,260
353
40
1,200
359
41
1,150
371
44
1,110
375
46
1,060
381
T3 HEATING SPEED
RISE
CFM
WATTS
45
1,415
327
47
1,360
335
48
1,305
343
50
1,260
353
53
1,200
359
55
1,150
371
58
1,110
375
X
1,060
381
23
T4 COOLING
SPEED
RISE
CFM
WATTS
X
1,305
311
X
1,265
320
26
1,225
325
27
1,180
334
28
1,140
338
29
1,095
349
30
1,050
350
32
1,010
357
T4 COOLING
SPEED
RISE
CFM
WATTS
36
1,305
311
37
1,265
320
39
1,225
325
40
1,180
334
42
1,140
338
44
1,095
349
46
1,050
350
48
1,010
357
T4 COOLING
SPEED
RISE
CFM
WATTS
49
1,305
311
50
1,265
320
52
1,225
325
54
1,180
334
56
1,140
338
58
1,095
349
X
1,050
350
X
1,010
357
T4 COOLING
SPEED
RISE
CFM
WATTS
33
1,335
320
34
1,305
331
35
1,265
343
37
1,225
343
38
1,190
343
40
1,135
351
42
1,095
358
44
1,040
367
T4 COOLING
SPEED
RISE
CFM
WATTS
43
1,335
320
45
1,305
331
47
1,265
343
49
1,225
343
51
1,190
343
53
1,135
351
55
1,095
358
58
1,040
367
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,440
426
1,390
428
1,365
440
1,335
440
1,295
456
1,255
456
1,220
465
1,180
468
T5 COOLING
SPEED
CFM
WATTS
1,637
444
1,593
454
1,541
459
1,497
473
1,450
478
1,407
485
1,357
493
1,304
502
T5 COOLING
SPEED
CFM
WATTS
1,637
444
1,593
454
1,541
459
1,497
473
1,450
478
1,407
485
1,357
493
1,304
502

Advertisement