A. Product Description:
A smart switch box allowing the user to have mechanical switches, electronic sensors, and Pro Spot proportional
switches to control a powered wheelchair. The device has 6 ports that are labeled, forward, reverse, left, right,
off and mode.
B. Key Features:
Allows a variety of switches to control drive input.
With the Pro Spot proportional switches attached the ability to have proportional switch drive
input.
C.
Compatibility:
1.
Penny and Giles R-Net - Omni is required
2.
Curtis Electronics Enable 50 - Enhanced Display is required
3.
Dynamic Controls - DX-ACC4B Switch Interface module from wheelchair manufacturer is required for
switched drive controls.
4.
For use with Invacare powerchair with Mark VI electronics, Sip-N-Puff/Digital Interface module (P/N:
SNPM6) is required from wheelchair manufacturer
SET-UP GUIDE
Cool Cube Owner's Manual
GENERAL SET UP

GENERAL USE

4 Switch Driving
1.
Activate the switch plugged into the forward port to send the powerchair forward.
2.
Activate the switch plugged into the reverse port to send the powerchair backwards or reverse.
3.
Activate the switch plugged into the left port to turn the powerchair left.
4.
Activate the switch plugged into the right port to turn the powerchair to the right.
5.
Activate the right or left port and forward or reverse port to move the chair in a diagonal movement.
*NOTE: refer to the picture above for the port order. Starting to the far left, the first port is for the right
direction, followed by the left, reverse and the forward direction on the far right.
3 Switch Driving
1.
Activate the switch plugged into the left port to turn the powerchair to the left.
2.
Activate the switch plugged into the right port to turn the powerchair to the right.
3.
Activate the switch plugged into the forward port to move the powerchair forward.
4.
Tap switch plugged into the forward port to switch the mode from driving forward to driving in reverse and
then push the switch plug into the forward port to move the powerchair in reverse.
5.
With Pro Spot switches press one of the switch plugs into either left or right port while pressing the switch
plugged into the forward port to move the chair in a diagonal direction.
249056 Rev. C
1.
Attach the Cool Cube to the Omni by the DB9 cable.
2.
Attach the various switches to be used with the device.
3.
Have the Dealer program the Cool Cube for the number
of switches attached.
5