1
Area depth angle adjustment
Depth angle
adjustment screw
for the Presence/Motion
area
When adjusting the 2nd row close to the door,
follow Table1 dipswitch18(Installation mode) for the easier adjustment.
When dipswitch 18 is set to "ON", sensor automatically set back to the operation mode after 5 minutes.
If the installation mode is required again, set dipswitch 18 to "OFF", then set to "ON".
Make sure that the detection area does not overlap with the door / header, and there is no highly reflecting
NOTE
object near the detection area otherwise ghosting / signal saturation may occur.
1-1 Presence/Motion area
Depth angle adjustment screw
Shallow
for the Presence/Motion area.
-2°
-6°
+4°
Use the area adjustment tool (A)
as shown above
-10°
+8°
to change the area depth angle.
Deep
Shallow
[feet,inch(mm)]
[feet,inch(mm)]
0
0
3'3"
3'3"
(1000)
(1000)
6'6"
6'6"
(2000)
(2000)
9'10"
9'10"
(3000)
(3000)
6'6"
3'3"
0
3'3"
0
3'3"
(2000)
(1000)
(1000)
(1000)
(2000)
2
Area width adjustment
2-1 Presence/Motion area
Adjust the Presence/Motion area width
with the Width adjustment screws.
Each side can be adjusted independently, allowing for
asymmetrical settings. Use the area adjustment tool (A)
to adjust area width.
When setting the Presense/Motion area width,
NOTE
make sure to turn the width adjustment screws
until it clicks.
Opens
Opens
1
9
All Areas
All Areas
elimination
elimination
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
3
Presence/Motion
area rows adjustment
Presence/Motion area rows can be adjusted
by changing the Dipswitches 6 & 7.
See 5.Dipswitch settings, Table 1.
5
Dipswitch settings
The area adjustment tool (C) can be used to change Dipswitch.
Table1
Setting
Function
Dipswitch
30sec.
60sec.
1
Presence timer
Dipswitch
1
2
1
2
2
Dipswitch
Setting1
Setting2
3
Frequency
Dipswitch
3
4
3
4
4
OFF
ON
Dipswitch
BLUEZONE
5
5
5
Dipswitch
6
5rows
4rows
Presence/Motion
area row adjustment
Dipswitch
6
7
6
7
7
8 9 10
1
2
3
4
5
Dipswitch
8
Approach area
Dipswitch
9
width adjustment
Dipswitch
10
Normal
Rain
Dipswitch
Rain mode
11
11
11
Normal
Snow
Dipswitch
Snow mode
12
12
12
Bi
Uni
Dipswitch
Direction
13
13
13
OFF
ON
Simultaneous
Dipswitch
14
output
14
14
All manuals and user guides at all-guides.com
Area adjustment tool
Depth angle
adjustment screw
for the Approach
area
A
1-2 Approach area
Depth angle adjustment screw
Deep
Shallow
for the Approach area.
-5°
-10°
Use the area adjustment tool (A)
as shown above
-15°
+10°
to change the area depth angle.
Deep
Shallow
[feet,inch(mm)]
[feet,inch(mm)]
0
0
3'3"
3'3"
(1000)
(1000)
6'6"
6'6"
(2000)
(2000)
9'10"
9'10"
(3000)
(3000)
13'12"
9'10"
6'6"
6'6"
6'6"
3'3"
0
(4000)
(3000)
(2000)
1000
(2000)
2-2 Approach area
Approach area width can be adjusted
by changing the Dipswitches 8,9,10.
See 5.Dipswitch settings, Table 1.
Left eliminated
Right eliminated
1 2 3
7 8 9
Width adjustment screws
1 2
8 9
1 2 3
7 8 9
elimination
elimination
elimination
elimination
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
4
Sensitivity adjustment
Adjust the Approach area and
Motion/Presence area with potentiometer.
Turning it clockwise increases the sensitivity and
turning counterclockwise lowers the sensitivity.
Presence/Motion
Approach sensitivity
sensitivity
Low
High
Use the area adjustment tool (B)
to change sensitivity.
Comment
180sec.
600sec.
To enable the presence detection, do not
enter the detection area for 10 seconds
after setting the timer.
1
2
1
2
Setting3
Setting4
When using more than one sensor close
to each other, set the frequency different
for each sensor.
3
4
3
4
When dipswitch 5 is set to "ON",
the BLUEZONE (1st row) is active and
looks through the threshold.
Rows can be eliminated as shown below.
5rows
4rows
3rows
3rows
2rows
6
7
6
7
6
7
8
1
8
2
7
3
6
4
5
The width of Approach area can be
Active area
adjusted by changing the Dipswitches as
Inactive area
shown the left.
Set this switch to "Rain" if the sensor is
used in a region with a lot of rain.
Set this switch to "Snow" if the sensor is
used in a region with snow or
a lot of insects.
When dipswitch 13 is set to "Uni",
*Please refer to
this setting enables the door to close
Table 2 for the
faster when a person walks away from
details.
the door.
When Dipswitch 14 is set to "ON", both
the activation & safety relay outputs will
operate simultaneously regardless of
detection area.
But only the Safety output relay
will respond back with a Safety output
when it receives a Test input.
Dipswitch
Safety output
B
15
(to door controller)
Test input
Dipswitch
16
(from the door controller)
Dipswitch
C
Future use
17
Dipswitch
Installation mode
18
Table 2
Bi-direction
Door
Deep
Sensor
Bi
Detection
area
13
CHECKING
Check the operation in the operation mode according to the chart below.
Outside of
Power
Entry
detection
OFF
area
Image
3'3"
0
(1000)
Status
-
Stand-by
Operation indicator
None
Green
OFF
Activation
14
output
ON
14
N.O.
OFF
15
N.C.
14
15
Safety
output
N.O.
ON
15
N.C.
14
15
NOTE
The response time may differ according to the color of the objects and the color/material of the floor.
7
8
9
INFORM BUILDING OWNER / OPERATOR OF THE FOLLOWING ITEMS
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth. Do not use any cleaner / solvent.
2. Do not wash the sensor with water.
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise an electric shock may occur.
4. When the operation indicator blinks green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
1. When turning the power ON, always walk-test the detection area to ensure the proper operation.
NOTE
2. Do not place any objects that move or emit light in the detection area. (e.g. plant, illumination, etc.)
TROUBLESHOOTING
Operation
Door operation
indicator
None
Wrong power supply voltage.
Door does not
open when a
Wrong wiring or connection failure.
person enters
Unstable
Wrong detection area positioning.
the detection
Sensitivity is too low.
area.
Short presence timer.
Dirty detection window.
Proper
Wrong wiring or connection failure.
Objects that move or
Door opens
Unstable
emit light in the detection area.
when no one
is in the
The detection area overlaps with
detection area.
that of another sensor.
(ghosting)
Waterdrops on the detection window.
2rows
Detection area overlaps with door /
header.
Sensitivity is too high.
Raining or snowing
Proper
Wrong setting of dipswitches
Door remains
Proper
Sudden change in the detection area.
open
Wrong wiring or connection failure.
Fast
Dirty detection window
Green
blinking
Sensor failure
Slow
Signal saturation
Green
blinking
The detection area overlaps with
the door / header.
Proper
Slow
Signal saturation (BLUEZONE)
operation
Green
blinking
Manufacturer
OPTEX Co.,LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
TEL.: +81(0)77-579-8700
FAX.: +81(0)77-579-7030
WEBSITE:
www.optex.co.jp/as/eng/index.html
N.O.
N.C.
Select "N.O." / "N.C." for Safety output.
15
15
High
Low
The delay time between Test input and
Safety output is 10msec..
16
16
Set dipswitch 18 to "ON" to adjust the 2nd
OFF
ON
row. During the installation mode only the
2nd row remains active and the operation
indicator shows yellow. After setting the
18
18
row, switch dipswitch 18 "OFF".
Uni-direction
Uni
13
Entry into
Entry into
Entry into
Entry into
Approach area
5th row
4th row
3rd row
(6th row)
Approach
Motion
detection active
detection active
detection active
Orange Blinking
Orange
Red
Possible countermeasures
Possible cause
Set to the stated voltage.
Check the wires and connector.
Check ADJUSTMENTS 1, 2 ,3 ,4 , 5.
Set the sensitivity higher.
Set the presence timer longer.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Check the wires and connector.
Remove the objects.
Check Table1 dipswitch 3 & 4.
Use the rain-cover. (Separately available)
Or wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Or install in a place keeping the waterdrops off.
Adjust the detection area to "Deep"(Outside).
Set the sensitivity lower.
Set dipswitch 11, 12 to "Rain","Snow".
Check Table 1 dipswitch 11, 12, 15.
Check ADJUSTMENTS 4 & Table 1 dipswitch 1, 2.
If the problem still persists, hard-reset the
sensor.(Turn the power OFF and ON again)
Check the wires and connector.
Wipe the detection window with a damp cloth.
Do not use any cleaner or solvent.
Contact your installer or service engineer.
Remove highly reflecting objects from the detection
area. Or change the area depth angle.
Adjust the detection area to "Deep"(Outside).
Remove highly reflecting objects from the detection
area. Or change the area depth angle.
North and South America Subsidiary
OPTEX INCORPORATED
East coast office
18730 S. Wilmington Avenue, Suite 100
8510 McAlpines Park Drive, Suite 108
Rancho Dominguez CA 90220 U.S.A
Charlotte, NC 28211 U.S.A.
TEL.: +1-800-877-6656
TEL.: +1-800-877-6656
FAX.: +1(310)898-1098
FAX.: +1(704)365-0818
WEBSITE: www.optextechnologies.com
WEBSITE: www.optextechnologies.com
: Detection
: Non-Detection
Entry into
Entry into
BLUEZONE
2nd row
(1st row)
Presence
Red
Blue
Blinking

Advertisement

loading