Download Print this page

Dialight ProSite Installation & Operation Instructions page 5

For cid2/ciid1/ciid2/ciii

Advertisement

NOTE: The DALI circuit in two power supply
luminaires are already internally wired as a
daisy chain to allow for commissioning and
discovery. The
Bus wire
connected to the DALI terminal block
positions in the wiring compartment.
NOTE: Make sure luminaires containing two
power supplies are grouped and scheduled
together for the luminaire to function in the
correct manner.
WARNING: Improper installation, operation,
or maintenance of this luminaire may result in
the invalidation of the warranty, certificate,
or declaration of conformity.
Maintenance / Inspection
This LED luminaire should require a minimum
amount of maintenance. If any unforeseen
repairs are required, please contact Dialight
or its authorized representative.
Within
the
scope
of
maintenance
inspection routine the following should be
included:
 Protective hoses should be covering the
connection cables.
 Cable entries must be free of corrosion.
 The lens should be cleaned periodically as
needed to ensure continued photometric
performance. Clean the lens with a damp,
non-abrasive,
lint
free
sufficient, use mild soap or a liquid cleaner.
 Inspect the luminaire to ensure that it is free
of any obstructions or contamination (i.e.
excessive dust build up). Clean with a non-
abrasive cloth if needed.
 Perform visual mechanical and electrical
inspections
on
a
regular
recommend routine checks to be made
on a yearly basis. Frequency of use and
environment should determine this.
It is recommended to follow an Electrical
Preventive
Maintenance
described in NFPA 70B: Recommended
Practice for Electrical Equipment.
9100FLM000906 REV B
Page 5 of 8
ProSite Floodlight for CID2/CIID1/CIID2/CIII
Repairs / Overhaul / Modification
The equipment must be operated according
to the intended purpose in a perfect and
needs to be
undamaged condition.
NOTE: Should the luminaire enclosure be
damaged, only a full luminaire replacement
will be permitted. In case of doubt, the
equipment should be returned to Dialight for
inspection/repair.
Disposal & Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal should be observed.
Secondary Retention Cable
Part Number
H6XCAB60
H6XCAB72
1. Read and follow all instructions in the
installation manual provided with the
secondary retention cable.
2. Connect the safety cable to one of the
or
retention brackets on the luminaire.
3. When using a safety cable for secondary
retention, ensure minimum slack in the
cable installation. The slack should be no
greater than 1 ft. [0.3 m]
NOTE:
Cable
attachment method to meet customer
application and to be appropriate with all
local and regional regulations.
cloth.
If
not
basis.
We
F1 Retention Bracket Locations
Program
as
Description
Secondary Retention
Cable, Stainless Steel, 60"
Secondary Retention
Cable, Stainless Steel, 72"
type, size, material, and
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: +1 732 919 3119 Fax: +1 732 751 5778
F1 Retention
Bracket
F2 Retention Bracket Locations
F2 Retention
Bracket
www.dialight.com

Advertisement