High Pot. And Insulating Resistance Tests; Factory Default Settings - TCL L39D3320 Service Manual

Table of Contents

Advertisement

Each panel has it's own colour coordinates, Please refer to the following table.
L32V6200/L32E5200
x
Normal
0.275
Cool
0.265
Warm
0.305
Expected Targets and Tolerances
The measured parameters should be "x, y" coordinates.
The White Balance alignment should be performed using a contact less analyzer (ei: Minolta
CA-210). The analyzer may not touch the screen surface, and measurement must be performed in a
dark environment keeping the probe(s) at 90+/-2° from the panel.
The result should measure up the relevant spec.

2.4 High Pot. and Insulating Resistance Tests

At the end of the process, a High Pot. and an Insulating Resistance tests are required for
matching Safety Electrical requirements (ei: xxxx)
High Voltage Withstanding requirements
- "Voltage"
- "Max Leakage Current"
- "Test Time"
Insulating Resistance requirements
- "Voltage"
- "Threshold Min"
- "Test Time"
Do the "Reset shop" before packing.The detail of reset shop follow OOB setting.
"Factory Menu" Definition
1)
Hotkey
Item
Sub-item
Hotkey
2) Burning Mode
L42E5200F/L42V6200F
y
x
y
0.310
0.275
0.290
0.285
0.265
0.290
0.330
0.305
0.330
3500 VAC
10 mA
5 sec
DC500V
4M
3 sec

3.Factory default settings

Value
Off/On
Page 8 of 12
Factory Alignment Specification of normal SIACP
C32E320/L32P60
x
y
0.280
0.290
0.270
0.280
0.312
0.330
Note
OFF hotkey is invalid
ON
hotkey(Return key) is availability
C42E320F/L42P60F
x
y
0.280
0.290
0.270
0.280
0.320
0.320