Initialization; Eeprom Data; High Voltage And Ib Value Limit Test( Random Test ); Heater Voltage Test ( Random Test ) - TCL 21M62S Service Manual

Chassis: m123sp
Table of Contents

Advertisement

TCL-THOMSON Electronics R&D Center (Shen'Zhen Lab)

10. High voltage and Ib value limit test( random test )

Instruments:
High voltage meter, Ib meter.
Input signal pattern: White vertical
Input signal intensity: 60dBuv (1 Mv rms)
Test means: Connect High voltage meter and Ib meter. Test voltage of different
Model

11.Heater voltage test ( random test )

Instruments
Input signal pattern
Input signal intensity
Connect the RMS voltage meter to the 2 ends of CRT glowers,test the heater voltage of
highest CR and Brightness, It should meet:6.3±0.3Vrms

12. CCD and VOL-CHIP function test

VOL-CHIP and CCD function test,please find the service manual in detail.

13. Initialization

Under the factory mode,press"SOUND"button,the screen displays"WAIT",
when the screen displays "OK", the initialization finished. You can enter the next
working procedure.
14.EEPROM DATA:
Note:the items with
*
parameter, other items are not, pls do not adjust them;
Use
TMPA8873*SANG(
Use
TMPA8873*SBNG(
Data
Model
RC*
南美 M123SP
40
20E10
40
Data
Model
HIGH6*
南美 M123SP
20E10
HIGH5*
南美 M123SP
20E10
M123SP 南美软件
Chassis Name
2006-04-29
Issued on
2006-07-29
Updated on
Ib separately, It should meet the requirements below:
Ib, Ib scope
Ib=50µA
Scope:
50µA&1200µA
:RMS voltage meter
: Philips test graphic
:1 mVrms(60dBuV)to 50 mVrms
are adjustable,the items with BLUE COLOR are work in CRT
13-PA8873-PSP),D-Mode\
G2_FLAG04 posit 00
13-PA8873-PSPB),D-Mode\
GC*
BC*
40
40
40
40
VP60
VLIN6*
26
00
0E
26
00
10
VP50
VLIN5*
26
06
0B
24
06
0B
Serial No.
Page
Version
16
Anode high voltage (Kv)
21"
Value
28.0±2.5
G2_FLAG04 posit 40
FAC 01
GD*
40
40
FAC 02
VSC6*
VBLK6
19
00
17
00
VSC5*
VBLK5
17
00
16
00
10 of 13
2.0
Diff.
<2
BD*
40
40
VCEN6*
2A
21
VCEN5*
2D
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents