Settings Screen
TOLERANCE – This button shows the percent allowance of tolerance before the audio alarm
will begin to count down.
TIME OUT OF TOLERANCE - Shows the amount of time out of tolerance before the audio
alarm will sound.
VOLUMES – This button can be set to gallons or liters. When it is set to gallons, all math will
use U.S. tons in the equations. When it is set to liters, all math will use metric tonnes for
factoring equations. All targets and flow rates will also be reflected as either the selected
gallons or liters.
FLOW RATE PER – This button can toggle between a rate of Gallons per hour/Liters per hour
and Gallons per minute/Liters per minute. Per hour or per minute will depend on the volume
selected and the calculated time needed to run the volume.
START DELAY – This button will allow you to set the delay of the start of the pump in seconds
once the start button has been pressed (Zero is an option). When you press START from the
RUNNING SCREEN this timer will count down before the pump actually begins. This is
implemented so that if plant issues occur with the AC pump, the ZycoTherm pump will not turn
on and off with every attempt of the AC pump.
CALIBRATION – This button is only available at the pump.