Summary of Contents for Roger Technology H70/200AC
Page 1
Quick Start H70/200AC Rev01 20/08/2020 H70/200AC is a range of 230V AC controllers and controls automations for gates with 1 or 2 asynchronous single phase ROGER motors. 1. Typical installation Power supply H70/200AC - Motors 3x1,5 mm double insulated cable (max.15 m) - 3x2,5 mm (max.
Page 2
2. Electrical connections RECOMMENDED USE for Series F2ES - F2S photocells 1 2 3 4 5 Accessories illustrated are indicative only 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 FUSE F630mA PROG TEST F630mA...
Page 3
4. Before starting ... a) Select the automation system model installed with the parameter A1. Standard motor (4-pole) - (MONOS4/200 and all existing codes with the exception of the following codes for the value A1 01) Slow motor (6pole) - (R20/302, R20/502, R21/368, H23/282, R41/832, R41/833) 1 MOTOR 2 MOTORS b) Select the number of motors installed with the parameter 70.
Page 4
5. Acquisition procedure (with encoder enabled, with or without limit switches - 75 01) 1. Press and hold PROG for 4 seconds. 2. APP- appears on the display. 3. Press PROG. 4. AUTO appears on the display. 5. MOTOR 1 starts opening at low speed. 6.
Page 5
Acquisition procedure (without encoder, only for opening limit switch) 1. Press and hold PROG for 4 seconds. 2. APP- appears on the display. 3. Press PROG. 4. MOTOR 1 starts opening at normal speed. 5. AP1 is shown on the display. 6.
Page 6
6. Setting basic parameters Position control Position control MOTOR 1 MOTOR 1 deceleration space MOTOR 1 deceleration space MOTOR 2 deceleration space Opening delay of MOTOR 1 Initial acceleration MOTOR 2 Position control when opening Initial acceleration when opening Initial acceleration when closing Opening delay of MOTOR 2...