Victron Energy Autotransformer 1. Safety • These instructions are for use by qualified personnel only. Do not perform any servicing or installation other than that specified in the operating instructions unless you are qualified to do so. Incorrect installation or servicing may result in a risk of electric shock, fire, or other safety hazards.
The Victron Energy Autotransformer has the ability to use a ground/earth relay to create a Neutral to Ground bond in the AT itself, if coupled with a Victron Energy MultiPlus or Quattro and the relay terminals are interconnected.
Page 5
Victron Energy Autotransformer See diagram below for wiring instructions. Page 3 Introduction...
Victron Energy Autotransformer 2.3.2. Stepping Up Voltage Alternative to Stacked Inverters. Loads such as deep well water pumps and air conditioning units sometimes require Split-Phase 120/240Vac power. When the available AC power source is not what is needed in the installation, the autotransformer can create the needed voltage by doubling the incoming voltage.
Victron Energy Autotransformer 2.3.3. Stepping Down Voltage Flexibility in Using Split-Phase for Single-Phase Inverters One case for using the autotransformer to step down voltage could be in installations that use a Split-Phase generator and a Single-Phase inverter, the autotransformer makes it possible to use all available power from both legs of the generator to power loads and to charge batteries.
Page 8
Victron Energy Autotransformer Page 6 Introduction...
Victron Energy Autotransformer 2.4. Ground Relay In most energy systems for residential or mobile use a TT configuration is used, which means the Neutral of the AC system is grounded. This is to ensure the GFCI breaker will trip in case there is an earth failure (The connection N/PE will ensure a current will flow in the secondary circuitry which is detected by the GFCI).
Victron Energy Autotransformer 2.6. Over Current Protection In case of over current the MCB will switch off. Disconnect some of the load. The MCB is for Over Current and Temperature Protection and switching the unit ON/OFF. 2.7. Sizing Limitations The Autotransformer comes in two models, a 32A model and a 100A model. This value is defined in the amount of current there can be in pass through, so in other words the current which is forwarded without being converted.
Victron Energy Autotransformer 3. Installation 3.1. Installation Considerations Ensure that the Autotransformer is used under the correct operating conditions. Never operate it in a wet or dusty environment. The AT is rated to IP21. Ensure that there is always sufficient free space around the product for ventilation (10cm or 4 inches), and that ventilation openings are not blocked.
Victron Energy Autotransformer 4. Specifications Autotransformer 32 A 100 A Input/output Voltage 120 / 240 V Input Circuit Breaker 32A, Two Pole 100A, Two Pole Frequency 50/60Hz Maximum 240 V Feed Through Current 100 A Neutral Current, 30 min 32A (3800 VA) Neutral Current, Continuous 28A @ 40ºC/100ºF...
Victron Energy to make such repairs. Non-compliance with the instructions in this manual will render the warranty void. Victron Energy is not liable for any consequential damages arising from the use of this product. The maximum liability of Victron Energy under this limited warranty shall not exceed the actual purchase price of the product.