Isolation Transformer
2000W | 3600W 115/230V
Rev 11 - 02/2023
This manual is also available in HTML5.

Advertisement

Table of Contents
loading

Summary of Contents for Victron energy 2000W

  • Page 1 ENGLISH Isolation Transformer 2000W | 3600W 115/230V Rev 11 - 02/2023 This manual is also available in HTML5.
  • Page 2: Table Of Contents

    Isolation Transformer Table of Contents 1. Safety Instructions ........................1 2. Features ..........................2 2.1. Electrical safety ......................2 2.2. Galvanic corrosion prevention ..................... 2 2.3. Converting voltages ......................3 2.4. Soft start ........................3 2.5. Internal wiring diagram ...................... 3 2.6.
  • Page 3: Safety Instructions

    Isolation Transformer 1. Safety Instructions WARNING: Before installing, using, storing or transporting this product, read and save the safety instructions below. General: • Review the related documentation of this product to familiarise yourself with safety markings and instructions before operating the equipment. This product has been designed and tested in accordance with international standards.
  • Page 4: Features

    Isolation Transformer 2. Features The isolation transformer eliminates any electrical continuity between AC shore power and the vessel. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. 2.1. Electrical safety Electrical safety is taken for granted in the case of a standard on-shore installation. A circuit breaker will trip, or a GFCI (Ground Fault Circuit Interrupter) will trip in case of a short circuit or a current leakage to ground.
  • Page 5: Converting Voltages

    50Hz to 60Hz or vice versa. 2.4. Soft start Soft start is a standard feature of a Victron Energy isolation transformer. It will prevent the shore power circuit breaker from tripping due to the transformer inrush current. 2.5. Internal wiring diagram...
  • Page 6: Safety When The Vessel Is Out Of The Water

    Isolation Transformer 2.6. Safety when the vessel is out of the water It is recommended, for optimal safety, to connect the shore earth to the vessel's earth when the vessel is out of the water, in winter or for maintenance. The isolation transformer has a facility for this. Page 4 Features...
  • Page 7: Installation

    (PE) when the vessel is out of the water for maintenance or winter storage. 1x long yellow/green wire with eye terminals, used for case grounding (not included for the 2000W model). 1x short yellow/green jumper wire with female 6.35 mm spade connectors, used to make AC output neutral (N) to earth (PE) link.
  • Page 8: Ac Input Configuration

    Isolation Transformer 3.3. AC Input configuration The AC input needs to be configured for 115 or 230V use. This is done by connecting male spade terminals using the black jumper wires (included). These terminals are located above the AC input connector. Connect AC input jumper cable...
  • Page 9: Connecting Ac Input And Ac Output

    Isolation Transformer Connect Connections AC output jumper cable voltage between J29 and J32 115V J31 and J25 230V J31 and J32 3.5. Connecting AC input and AC output Shock hazard. Do not work on the isolation transformer or the electrical system if still connected to an electrical power source.
  • Page 10: Ac Output Neutral To Earth Link

    To link the AC output neutral (N) to earth (PE), place a green/yellow jumper wire (included) between the J33 and J21 male spade connectors. AC output neutral (N) to earth (PE) link. 3.7. Cable cross-section requirements Use the following minimal cable cross-sections: Isolation transformer power rating Voltage Metric 2000W 115V 2.5mm² AWG 13 2000W 230V 1.5mm² AWG 16...
  • Page 11: Wiring Example

    Isolation Transformer 3.8. Wiring example Wiring example isolation transformer installed on a vessel connected to shore power. Description Shore power. Circuit breaker. GFCI (Ground Fault Circuit Interrupter). Shore cable. Isolation transformer. AC loads. 3.9. Linking input and output earth when the vessel is out of the water. For safety reasons, when the vessel is out of the water (on land) during winter or for maintenance, the vessel's earth (PE) conductor must be connected directly to the shore power earth (PE) conductor.
  • Page 12: Operation

    Isolation Transformer 4. Operation Check the input and output voltage configuration before operating the isolation transformer. 4.1. Inrush current limiter The inrush current limiter prevents upstream circuit breakers from tripping when switching on the isolation transformer. 4.2. Temperature protection The isolation transformer is fan cooled. The fan speed is temperature-controlled. Its speed (rpm) will increase if the temperature increases.
  • Page 13: Technical Specifications

    Isolation Transformer 5. Technical specifications Isolation Transformer 2000 Watt 3600 Watt AC input voltage * 115 or 230V 115 or 230V AC output voltage * 120 or 240V 120 or 240V Frequency 50/60Hz 50/60Hz 19A (115V) 32A (115V) Output current rating 8.5A (230V) 16A (230V) Soft start...
  • Page 14: Dimensions

    Isolation Transformer 6. Dimensions 2000W model Page 12 Dimensions...
  • Page 15 Isolation Transformer 3600W model Page 13 Dimensions...