LIMITED WARRANTY ....................SPECIFICATIONS ....................... NOTES .......................... 8 CALIBRATION INTERVAL To ensure the accuracy of the PS-2010 Series, BC Group International, Inc. recommends that it be calibrated at least once every 12 months. Calibration must be done by qualified personnel.
Page 4
CAUTION - SERVICE The PS-2010 is intended to be serviced only by authorized service personnel. Troubleshooting and service procedures should only be performed by qualified technical personnel.
Page 5
A mild detergent can be used if desired. CAUTION - LIQUIDS Do not submerge or spill liquids on the PS-2010 Series. Do not operate the PS-2010 Series if exposed to fluid. CAUTION - ENVIRONMENT...
Page 7
NOTICE – SYMBOLS Symbol Description Caution (Consult Manual for Further Information) Center Negative Per European Council Directive 2002/95/EC, do not dispose of this product as unsorted municipal waste. IEC Measurement Category I – CAT I equipment designed to protect against transients in equipment on circuits not directly CAT I connected to MAINS.
Page 9
BC BIOMEDICAL PS-2010 PATIENT SIMULATOR The Model PS-2010 is a Microprocessor based Patient Simulator. It provides ECG Simulation with four waveforms with constant QRS duration and six machine performance testing waveforms. The following are highlights of some of the main features: •...
LAYOUT • This section looks at the layout of a PS-2010 and gives descriptions of the elements that are present. High Level Lead Test Universal Patient Output (+) Terminals Lead Connectors: • V2/C2 10 Waveforms with • V3/C3 LED Indicators for •...
Universal Patient Lead Connectors The 10 Universal Patient Lead Connectors allow for 12 lead ECG simulation with independent outputs. AHA and IEC color-coded labels are located on the face of the unit to aid in connecting the corresponding AHA and IEC Patient Leads. AHA Label IEC Label Description...
Page 12
representation. This waveform is then sent through a resistor network, developing the appropriate signals on the output terminals. Lead Test Terminals There are two test terminals on the top of the unit that allow for a quick test of the continuity of the lead cables.
Page 13
present level and flash. This sequence will continue while the key is depressed. Battery The unit utilizes a 9 Volt Alkaline Battery in the rear battery compartment. When the unit detects a LOW BATTERY, the LED in the lower right of the face will light, indicating the need to change the battery.