    BC BIOMEDICAL CQM-2000 Series TABLE OF CONTENTS WARNINGS, CAUTIONS, NOTICES ................ii DESCRIPTION ....................... 1 MANUAL REVISIONS ....................2 LIMITED WARRANTY ....................2 SPECIFICATIONS ......................3 NOTES ........................... 4 CALIBRATION INTERVAL To ensure the accuracy of the CQM-2000, BC Group International, Inc. recommends that it be calibrated at least once every 12 months.
  • Page 3 WARNING - USERS The CQM-2000 is for use by skilled technical personnel only. WARNING - USE The CQM-2000 is intended for testing only should never be used in diagnostics, treatment or any other capacity where they would come in contact with a patient. WARNING - MODIFICATIONS The CQM-2000 is intended for use within the published specifications.
  • Page 4 CAUTION - SERVICE The CQM-2000 is intended to be serviced only by authorized service personnel. Troubleshooting and service procedures should only be performed by qualified technical personnel. CAUTION - CLEANING Do not immerse. The CQM-2000 should be cleaned by wiping gently with a damp, lint-free cloth.
  • Page 5 FOR INACCURACIES. NOTICE – CONTACT INFORMATION BC BIOMEDICAL BC GROUP INTERNATIONAL, INC. 3081 ELM POINT INDUSTRIAL DR. ST. CHARLES, MO 63301 1-800-242-8428 1-314-638-3800 www.bcgroupintl.com sales@bcgroupintl.com CQM-2000 Series User Manual Copyright © 2020 www.bcgroupintl.com Made in the USA 01/20 Rev 05...
  • Page 6: Description

    BC BIOMEDICAL CQM-2000 Series REM/ARM/CQM TEST MODULE This manual covers the model CQM-2000 and CQM-2100 REM/ARM/CQM Test Module. The term CQM-2000 will be used to apply to both models. Sections specific to the CQM- 2100 model will use the term CQM-2100 exclusively.
  • Page 7: Manual Revisions

    MANUAL REVISIONS Revision # Revisions Made Rev 01 Origination Rev 02 Updated Format Rev 03 Updated Format Rev 04 Format Updated, Misc. Edits Rev 05 Addition of CQM-2100, Misc. Edits LIMITED WARRANTY WARRANTY: BC GROUP INTERNATIONAL, INC. WARRANTS ITS NEW PRODUCTS TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP UNDER THE SERVICE FOR WHICH THEY ARE INTENDED.
  • Page 8: Specifications

    SPECIFICATIONS RESISTANCE 0 to 210 Ω RANGE (CQM-2000) 0 to 1110 Ω RANGE (CQM-2100) ± 0.5% Setting + 0.5 Ohm ACCURACY (NOTE: Accuracy after subtraction of zero resistance.) CONNECTIONS Safety Jack, 4 mm ENVIRONMENTAL AND PHYSICAL OPERATING RANGE 15° to 40° C (59° to 104° F) STORAGE RANGE -20°...