output timing of SN75LVDS82DGG (Texas Instruments) or equivalent.
Item
Data CLK
H-section
Display Area
Blanking
V-section
Display Area
Blanking
Frame Rate
Note : DE mode only
document version 1.0
NUMPAGES |29}
Product Specification
AU OPTRONICS CORPORATION
Symbol
Tclk
Period
Th
Tdisp(h)
Tblk(h)
Period
Tv
Tdisp(v)
Tblk(v)
F
Min
Typ
40
75
1034
1060
960
960
74
100
1088
1120
1080
1080
8
40
50
60
M240HW01 V2
Max
Unit
90
[MHz]
2047
[Tclk]
960
[Tclk]
1087
[Tclk]
2047
[Th]
1080
[Th]
967
[Th]
75
[Hz]