Trane 4PXCAU24BS3HAB Installer's Manual

Advertisement

Quick Links

Installer's Guide
Cased Aluminum Coils
"Dedicated Upflow / Downflow"
Convertible to horizontal with separately purchased kit
Upflow models:
4PXCAU24BS3HAB
4PXCAU32BS3HAB
4PXCBU24BS3HAB
4PXCBU30BS3HAB
4PXCCU30BS3HAB
4PXCBU36BS3HAB
4PXCCU36BS3HAB
4PXCBU42BS3HAB
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT - This Document is customer property and is to remain with this unit. Please return to service information pack
upon completion of work.
!
WARNING
WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pressure.
Recover refrigerant to relieve pressure before opening
the system. See unit nameplate for refrigerant type. Do not
use non-approved refrigerants, refrigerant substitutes, or
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives
could result in death, serious injury, or equipment damage.
!
This product can expose you to chemicals including
lead, which are known to the State of California to case
cancer and birth defects or other reproductive harm.
For more information go to www. P65Warnings.ca.gov
A. GENERAL
These coils are designed for use in combination with a heat pump
or cooling outdoor section using R-410A REFRIGERANT.
The 4PXC equipment has been evaluated in accordance with
the Code of Federal Regulations, Chapter XX, Part 3280 or the
equivalent. "Suitable for Mobile Home use" The height of the
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damage. Notify the transportation
company immediately if the coil is damaged.
B. APPLICATION INFORMATION
NOTE: 4PXC upflow coils may be installed in Upflow, Down-
flow, Horizontal Right with kit, and Horizontal Left with kit.
4PXC downflow coils may be installed in Downflow and
Horizontal Right with kit.
1.
FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air)
of the furnace.
4PXCCU42BS3HAB
4PXCBU48BS3HAB
4PXCCU48BS3HAB
4PXCDU48BS3HAB
4PXCCU60BS3HAB
4PXCDU60BS3HAB
WARNING
Downflow models:
4PXCBD30BS3HDB
4PXCBD36BS3HDB
4PXCCD36BS3HDB
4PXCBD42BS3HDB
4PXCCD42BS3HDB

Table of Contents

General .................................................................................1
Application Information ......................................................1
Recommendation ................................................................2
Furnace in Upflow Position ................................................2
Furnace in Downflow Position ...........................................2
Maximum Airflow Setting, CFM ..........................................3
Installing / Brazing Refrigerant Lines ................................3
Leak Check...........................................................................4
Condensate Drain Piping ....................................................4
Cleaning the Coil .................................................................4
Outline Drawings .................................................................5
NOTE:
OPTIONAL DOWNFLOW GASKET INSTALLATION: For
unusually humid applications that expect prolonged
operation above 70% RH, it is recommended to use the
BAYGSKT001A0 gasket kit to prevent water from forming
on the bottom of the drain pan and dripping into the
supply ductwork.
2.
INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat
pump or cooling combinations approved for these coils.
IMPORTANT: Review your installation requirements. Check
the table on the outline drawings and note all dimensions
for your coil before beginning the installation.
18-AD41D1-1B-EN
4PXCCD60BS3HDB
4PXCDD60BS3HDB
Figure 1

Advertisement

Table of Contents
loading

Summary of Contents for Trane 4PXCAU24BS3HAB

  • Page 1: Table Of Contents

    18-AD41D1-1B-EN Installer’s Guide Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit Upflow models: Downflow models: 4PXCAU24BS3HAB 4PXCBD30BS3HDB 4PXCCU42BS3HAB 4PXCCD60BS3HDB 4PXCAU32BS3HAB 4PXCBD36BS3HDB 4PXCBU48BS3HAB 4PXCDD60BS3HDB 4PXCBU24BS3HAB 4PXCCD36BS3HDB 4PXCCU48BS3HAB 4PXCBU30BS3HAB 4PXCBD42BS3HDB 4PXCDU48BS3HAB 4PXCCU30BS3HAB 4PXCCD42BS3HDB 4PXCCU60BS3HAB 4PXCBU36BS3HAB 4PXCDU60BS3HAB...
  • Page 2: Recommendation

    Set the coil case on top of the furnace. Connect the Model Number Horizontal Kit No. ductwork to the coil case using field supplied screws. 4PXCAU24BS3HAB See Figure 3. 4PXCAU32BS3HAB c. Secure the coil case to the furnace and seal for air...
  • Page 3: Maximum Airflow Setting, Cfm

    Installer’s Guide a. Lay the coil on its back side. F. MAXIMUM AIRFLOW SETTING, CFM b. Locate the 4" wide gasket material found in NOTE: BAYGSKT001A0. Water blow-off could occur in certain installation posi- c. Attach the 4" gasket material to three sides of the bottom tions if the airflow setting exceeds the maximum values of the drain pan as shown.
  • Page 4: Leak Check

    Installer’s Guide I. CONDENSATE DRAIN PIPING Capillary tubes will come Condensate drain connections are located in the drain pan at the out the top of bulb when bottom of the coil/enclosure assembly. The female threaded fitting positioned correctly. protrudes outside of the enclosure for external connection. A field fabricated trap is not required for proper drainage due to the positive pressure of the furnace;...
  • Page 5: Outline Drawings

    Installer’s Guide 18-AD41D1-1B-EN...
  • Page 6 Installer’s Guide 18-AD41D1-1B-EN...
  • Page 7: Troubleshooting Indoor Txv / Cooling Mode

    Installer’s Guide Before starting, insure the blower wheel, indoor and outdoor Troubleshooting Indoor TXV / Cooling Mode coils are clean. Correct air Is sub cooling at the Is superheat Is air flow at least flow outdoor unit between < 5F? 350 CFM per ton? problem 8 to 12F?
  • Page 8 About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

This manual is also suitable for:

4pxcau32bs3hab4pxcbu24bs3hab4pxcbu30bs3hab4pxccu30bs3hab4pxcbu36bs3hab4pxccu36bs3hab ... Show all

Table of Contents