still pressing the STOP button, press the Forward Skip/Search
button for at least 2 seconds. The unit enters Self-Diagnostic
Mode and display "TEST".Then an error code (e.g. H01) is
displayed, if any. In the case of no error, "TEST" is displayed on
FL.
4. If more than 1 error exists, the display will sequentially show the
respective error codes each time the STOP button is pressed.
5. Press "Stop" to indicate Error code.ve).
~ If several problem exist, error code will change each time when
"Stop" is pressed.
(e.g. F15
H15
9.2. Clearing all error code
1. Press and hold STOP button for 5 seconds.
2. FL indicator shows "CLEAR" for 1 second and change to "TEST".
9.3. Cancelling the Self-Diagnostic mode
1. Press the "Power" button to turn off the system. Press the
"Power" button again to turn on the system.
9.4. Description of error code
9.4.1. Power Amplifier Failure (F76)
When power amplifier output failure for power supply failure.
9.4.2. Error detection for CD Block
Error Code
Problem Condition
F15
CD does not function REST SW detection error.
H15
The CD tray closes
F26
CD does not function Transmission error between CD servo LSI and micon.
9.4.3. Error dection code for MD block
F26 ..... etc.)
This error occurs when the Optical Pick Up REST SW (S701)
detected within the specified time. (about 8 seconds).
CD disc tray detect switch NG. (Check and replace)
This error occurs between CD servo LSI and micon. This error
when the POWER is ON for the CD block and an error is detected
the transmission hasstarted.