YOUR NEW MACHINE:
When you receive your new machine, examine
the packaging for signs of shipping damage.
Carefully unpack the machine and inspect it. If
you see evidence of damage to the container or
the contents, contact the freight carrier
immediately.
Additionally, ensure all parts and accessories are
present; if you notice anything missing, contact
your distributor without delay.
SYSTEM FEATURES:
HEAT: The Prospector PE500 has a built-in heater
for the solution. An ON/Off switch activates the
heater. If you prefer to clean without the added
effectiveness of heat, simply do not turn on the
heat switch.
VACUUM: The vacuum motors provides an
excellent ratio of water lift to air movement (see
specs, page2). Carpets should dry quickly if not
over-wetting while cleaning.
PUMP: The pump is a piston style, positive
displacement pump. It runs continuously when
turned on, but the use of the unloader valve
enables the operator to set the pressure to the
desired PSI, between 50 and 500.
CHEMICALS:
The use of clear water in the machine is
recommended, within the application of
properly diluted cleaner as a pre-spray on the
area to be cleaned; however, you may mix
water and cleaning chemicals in a bucket --
according to directions on the chemical label --
and then pour into the solution tank. If you
chose to use chemicals in the machine, always
use a cleaner with a pH as close to neutral as
possible to avoid premature wear of the pump,
seals, and/or other components. Damage
caused by the use of strong chemicals is not
covered by the warranty.
The use of powder chemicals is discouraged;
unless they are mixed very thoroughly and rinsed
out completely at the end of the job, powdered
cleaners could cause a build-up in the pump,
lines, heater and/or quick disconnect. Any
problem caused by a chemical build-up is not
covered by warranty.
If foaming occurs as you clean, use a defoamer,
either in the recovery tank or on the area being
cleaned, to prevent overflow which can cause
water damage to machine components.
Use only manufacturer's recommended tools and
TOOLS & ACCESSORIES:
accessories. If the spray valve on your cleaning
tool begins to leak or if the spray tips get worn
and are no longer providing a nice even spray
pattern, order replacements from your
distributor.
CARE AND MAINTENANCE:
For continual peak operation, clean the internal
plumbing by rinsing with clear water at the end
of each job. About once a month, rinse the
machine with a commercial flushing compound
to break-up any mineral or chemical
accumulation that may have formed from the use
of hard water or chemicals.
The vacuum motors and the pump do not require
any scheduled maintenance; however, the
vacuum motor may require replacement brushes
after 750-1000 hours.
To help maintain a professional image; clean the
exterior of the machine with an all purpose
detergent, and protect it with automobile interior
polish. Lubricate the wheels, castors, and quick
disconnects with an all purpose, silicone spray.