Description
The KNX eTR 201/202 Sunblind push button has touch-sensitive buttons with
which functions can be called up in the KNX building bus system. The glass surface
is printed with areas for setting the temperature and solar protection. White LEDs
are integrated in these areas and their behaviour can be adjusted.
A temperature sensor is integrated into KNX eTR 201/202 Sunblind. An external
temperature reading can be received via the bus and processed with its own data
to create a total temperature (mixed value).
The KNX eTR 201/202 Sunblind has a PI controller for heating and cooling. The
setpoint temperature can be changed using the "+" and "-" touch buttons.
Communication objects can be linked via AND and OR logic gates.
Functions:
Operating zone for temperature control with 2 areas (warmer, cooler)
LEDs can be set. All LEDs Off, all LEDs as ambient lighting, all LEDs
individually controllable
Area function when touching two or more push buttons. Can be
configured as switch, selector switch, as 8 or 16 bit encoder or for scenario
recall
Temperature measurements. Mixed value from own measured value and
external values (proportion can be set by percentage), output of minimum
and maximum values
PI-controller for heating (one or two-level) and cooling (one or two-
level) according to temperature. Regulation according to separate setpoints
or basic setpoint temperature
2 AND and 2 OR logic gates each with 4 inputs. 8 logic inputs (in the form
of communications objects) can be used as inputs for the logic gates. The
output from each gate can be configured optionally as 1-bit or 2 x 8-bit
Additional functions KNX eTR 201 Sunblind:
1 operating zone for blinds, awnings, shutters or windows with 2 areas
(up/down with short/long distinction)
Additional functions KNX eTR 202 Sunblind:
2 operating zones for blinds, awnings, shutters or windows with 2 areas
(up/down with short/long distinction)
Configuration is made using the KNX software ETS 5. The product file can be
downloaded from the ETS online catalogue and the Elsner Elektronik website on
www.elsner-elektronik.de in the "Service" menu.

1.0.1. Area function

If the area function in ETS has been activated, another function is available along-
side the regular key functions. This is triggered by touching multiple keys, e.g. if
you touch the sensor with the palm of your hand.
Using the area function
If a key is pressed and another (different) key is touched within 0.2 seconds, the ac-
tion set in the ETS is performed for the area operation (See Fig. 1 a) and b)). The
keys are then blocked for 0.5 seconds.
Using the normal key function
If a key is pressed and no other key is touched within 0.2 seconds, the normal key
function is enabled/provided for 5 seconds (See Fig. 1 c) and d)). This is extended
for 5 seconds with each push of the button.
KNX eTR 201/202 Sunblind push button
Area function
readiness
0s
0.2s
Area function examples
Design
Area function
Key Y
a)
Key X
Design
Area function
b)
Key X
Key Y
KNX eTR 202 Sunblind:
Item numbers
Examples of normal key functions
71100 (white),
c)
Key X
71102 (black)
Design
Function X
Key X
d)
If the area function in the ETS is disabled, the keys can be used normally at any ti-
me.

1.0.2. Scope of delivery

Room temperature controller with mounting
4 screw anchors 4 × 20 mm, 4 flat head screws 3 × 25 mm

1.1. Technical specifications

Housing
Colours
Mounting
Degree of protection
Dimensions
Total weight
Ambient temperature
Ambient air humidity
Operating voltage
Bus current
Data output
Group addresses
Allocations
Communication objects
Temperature measure-
ment range
Temperature resolution
The product conforms with the provisions of EU guidelines.

1.1.1. Accuracy of the measurement

Measurement variations from permanent sources of interference (see chapter Ins-
tallation position) can be corrected in the ETS in order to ensure the specified ac-
curacy of the sensor (offset).
When measuring temperature, the self-heating of the device is compensated.
2.
Installation and commissioning

2.1. Installation notes

Installation, testing, operational start-up and troubleshooting should
only be performed by an electrician.
CAUTION!
Live voltage!
There are unprotected live components inside the device.
National legal regulations are to be followed.
Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.
Do not use the device if it is damaged.
Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is
no longer guaranteed.
The device is only to be used for the intended purpose described in this manual.
Any improper modification or failure to follow the operating instructions voids any
and all warranty and guarantee claims.
After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.
The device may only be used as a fixed-site installation; that means only when as-
sembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.
KNX eTR 201/202 Sunblind push button • Version: 26.10.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
Fig. 1
Key function readiness
5.2s
0.5 s block
0.5 s block
Design
Function Y
Key Y
Key function readiness
Key function readiness
plastic material, glass
• similar to RAL 9003 signal white
• similar to RAL 9005 jet black
on-wall (directly or with a socket
60 mm,
Ø
resp. cavity wall socket for hole
Ø
68 mm)
IP 10
housing approx. 81,5 x 81,5 (W x H, mm),
mounting depth approx. 12 mm
approx. 70 g
Operation 0...+55°C, storage -30...+85°C
5...95% RH, avoid bedewing
KNX bus voltage
max. 25 mA
KNX +/- bus terminals
max. 254
max. 254
KNX eTR 201 Sunblind: 92
KNX eTR 202 Sunblind: 98
0...+55°C
0.1°C
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.

2.2. Installation position

The KNX eTR 201/202 Sunblind push button is made for wall mounting. The
device can be mounted directly on plaster or on a socket (Ø 60 mm).
May be installed and operated in dry interior rooms only.
Avoid condensation.
When selecting an installation location, please ensure that the measurement re-
sults are affected as little as possible by external influences. Possible sources of in-
terference include:
Direct sunlight
Drafts from windows and doors
Draft from ducts which lead from other rooms or from the outside to the
junction box in which the sensor is mounted
Warming or cooling of the building structure on which the sensor is
mounted, e.g. due to sunlight, heating or cold water pipes
Connection lines and ducts which lead from warmer or colder areas to the
sensor
Measurement variations from permanent sources of interference can be corrected
in the ETS in order to ensure the specified accuracy of the sensor (offset).

2.3. Composition of the device

1
2
Fig. 2
Front view
1 „Temperature" area with 2 touch surfaces and temperature display
2 „Sun protection/drive" area with 2 touch surfaces
Fig. 3
3
4
4
Back view with mounting (KNX eTR 201)
3/4 Screw holes for different sockets. Fas-
tening with 2 screws is sufficient. For
3
3
wall mounting, use a fixing material
suitable for the ground!
5 KNX bus terminal +/- for connection
when mounted on a socket
6 Spring-loaded terminals KNX bus for
4
4
mounting directly on the wall
3
5
6
Fig. 4
Back view without mounting (KNX eTR
201)
5 KNX bus terminal +/- for connection
when mounted on a socket
6 Spring-loaded terminals KNX bus for
mounting directly on the wall
7 Programming LED
8 Programming button (recessed) for
teaching device
9 Temperature sensor
PRG key is accessible from below/outside
5
7
8
6
9
when the device is mounted (see chapter
Addressing the device).

2.4. Mounting

Prepare the device
Remove the front panel from the mounting. Release the lock by moving the front
panel a few millimetres upwards. The two parts can then be easily separated (Fig.
4).
Fig. 5 Locking of front panel and mounting
1
1
2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX eTR 201 Sunblind and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for elsner elektronik KNX eTR 201 Sunblind

  • Page 1 KNX eTR 201/202 Sunblind push button • Version: 26.10.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250...
  • Page 2 (target temperature is lo- wered) KNX eTR 201/202 Sunblind push button • Version: 26.10.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250...

This manual is also suitable for:

Knx etr 202 sunblind

Table of Contents