Siemens SIMATIC NET Installation Manual page 47

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
HV Impulse
Oscillatory
Magnetic Field
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-21-1
IEC 60068-21-2
Military Standard Tests
38
Description
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Damped
Enclosure Ports
Test
Cold Temperature
Humidity (Damp Heat, Cyclic)
Test
MIL-STD-901D
Shock (Hard-Mounted)
MIL-STD-167-1
MIL-STD-461E
Electromagnetic Interference
MIL-STD-1399
MIL-STD-810F
Storage, Low Pressure Altitude
Operational, High Temperature
Storage, High Temperature
Operational, Low Temperature
Storage, Low Temperature
Operational, Temperature Shock
Storage, Humidity, Acceleration,
Salt Fog and Vibration
MIL-STD-1275B
Description
Dry Heat
Vibration
Shock
Description
Vibration
Magnetic Field – DC
Magnetic Exposure
Low Pressure Altitude
Power Quality
Test Levels
1 kV differential mode @ 1 MHz
2.5 kV Common
1 kV differential mode @ 1 MHz
5 kV (Fail-Safe Relay Output)
5 kV
5 kV
2 kV
2 kV
2 kV
100 A/m
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (Non-Condensing),
55 °C (131 °F), 6 Cycles
2g @ 10-150 Hz
30 g @ 11 ms
Test Levels
Grade A, Equipment Class
I, Shock Type A Equipment
Type I (4-33 Hz)
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
Section 070, Part 1
Method 500 Series Procedures
Per Standard
Installation Manual, 04/2022, C79000-G8976-1342-09
RUGGEDCOM M2100F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ruggedcom m2100f