hyDRAuLIC FLuID AND INLET FILTER
• Check the hydraulic fluid level in the log splitter reservoir tank
before each use. Maintain the fluid level within the range specified
on the dipstick at all times.
• Change the hydraulic fluid in the reservoir every 100 hours of
operation. Follow the steps below:
1. Disconnect the suction hose from the bottom of the reservoir tank.
2. Carefully unthread the inlet filter and clean it with penetrating oil.
See Figure 5-2.
3. Allow the fluid to drain into a suitable container.
4. Reinsert the filter and refill the reservoir with three (3) gallons of oil.
Approved fluids include Dexron® III / Mercon® automatic transmis-
sion fluid or a 10 Weight AW hydraulic oil.
• Maintain the fluid level within the range specified on the dipstick at
all times.
NOTE: Always dispose of used hydraulic fluid and engine oil at
approved recycling centers only.
• Contaminants in fluid may damage the hydraulic components.
Flushing the reservoir tank and hoses with kerosene whenever
service is performed on the tank, hydraulic pump or valve is
recommended. Any repair to the hydraulic components should be
performed by a Sears Service Center.
WARNING
U
se extreme caUtion when working with kerosene
.
flammable flUid
hydraulic Filter
• Change the hydraulic filter every 50 hours of operation. Use only a
10 micron hydraulic filter. Order part number 723-0405.
bEAm AND SpLITTING WEDGE
• Before each use, lubricate both sides of the beam (where it comes
into contact with the splitting wedge) with engine oil. The wedge
plate on the log splitter is designed so the gibs on the side of the
wedge plate can be removed and rotated and/or turned over for
even wear.
• Make certain to readjust the adjustment bolts so the wedge moves
freely, but no excess space exists between the wedge plate and the
beam.
MAINTENANCE
ENGINE
Check Engine oil
1. Stop the engine and wait several minutes before checking the oil
2. Remove the oil fill dipstick.
3. Check the oil level on the dipstick. With the engine on level ground,
. i
t is an extremely
4. Replace the dipstick and tighten.
Changing Engine oil
Only use high quality detergent oil rated with API service classification
SF, SG, or SH. Select the oil's SAE viscosity grade according to the
expected operating temperature. Follow the chart below:
Colder
17
Figure 5-2
level.
the oil must be to the FULL mark on the dipstick.
5W30
Oil Viscosity Chart
Warmer
SAE 30