Trane AFDG Installation, Operation And Maintenance Manual page 15

Air-cooled adaptive frequency drive with tracerĀ® adaptiview control
Table of Contents

Advertisement

Figure 4.
AFDG (remote-mounted) cabinet dimensions: Frame F4, in.
9.10
20.70
3.90
1.85
2.80
2.80
120VAC
CONTROL
7.90
15.60
1.88
LOW VOLTAGE
WIRING
7.90
1.13
30.48
5.83
2X1 TERMINAL
STRIP
Adaptive Frequency
Drive for Chillers
WARNING LABEL
HAZARDOUS VOLTAGE
SERVICE
10.00
ACCESS
CIRCUIT
DOOR
BREAKER
86.81
10.00
47.76 (L3)
69.50
43.22 (L2)
38.68 (L1)
38.00
30.60 MAX
26.80 MIN
(L1-L2-L3)
3.29
25.16
21.020
17.30
18.660
RECOMMENDED
MOUNTING HOLES
1.400
2.580
3.260
3.640
1.280
2.460
3.760
24.210 RECOMMENDED
MOUNTING HOLES
2.580
26.570
1.400
28.930
31.61
NOTES:
1. FAILURE TO REMOUNT CABINET FLOOR GLAND PLATES
WILL HAVE A NEGATIVE INFLUENCE ON THE UNIT'S INTERNAL
COOLING CAPACITY AND CAN CAUSE TRIP FAULTS.
2. MAXIMUM CABLE LENGTH BETWEEN DRIVE AND MOTOR
SHOULD BE 100 FEET OR LESS.
PERMISSIBLE WIRE
3. CUSTOMER PROVIDED LOAD LUGS TO BE CRIMP ON
CONNECTION FOR BOLT ON LUG.
ENTRY AREA
Important:
If wiring to the right-most cabinet, refer to
Danfoss manual BAS-SVX21*-EN (High
power Drive Operating Instructions: TR200)
for special sealing instructions. The gland
plate must be fitted to the frequency
converter to ensure the specified protection
degree, as well as ensuring proper cooling
of the unit. If the gland plate is not mounted,
AFDG-SVU01L-EN
(149.83)
TOP VIEW
23.62
23.62
FRONT VIEW
18.03
2.80
8.48
12.43
3.640
3.640
3.640
3.640
3.640
1.280
1.280
1.280
1.280
1.280
2.460
2.460
2.460
2.460
2.460
16.340 RECOMMENDED
16.340 RECOMMENDED
MOUNTING HOLES
MOUNTING HOLES
18.700
18.700
21.060
21.060
23.62
23.62
(149.83)
BOTTOM VIEW
18.74
( 6.54) CHOKE ID
12X RECOMMENDED LIFTING POINT
47.24
22.61
8X MAGNETIC CORE CHOKES
2.05 TYP
6.78
3.16
18.13
A
3.640
3.640
1.280
1.280
2.460
2.460
39.960 RECOMMENDED
16.340 RECOMMENDED
MOUNTING HOLES
MOUNTING HOLES
42.320
18.700
44.680
21.060
47.24
23.74
the frequency converter may trip on
Alarm 69, Pwr. Card Temp.
Drive and Cabinet
AIR FLOW
2.50
13.04 MIN
CLEARANCE
A
2.50
AIR FLOW
11.73
18.86
2.91
2X1 TERMINAL STRIP
1.13
14.69 (T3)
16.56 (T2)
18.43 (T1)
L1-L2-L3
(11.93)
OUTSIDE OF
16.90 MIN / 22.50 MAX
BRACKETS
10.10 (GND)
AIR FLOW
89.88
AIR FLOW
89.17
71.36
26.58 SERVICE ACCESS DOOR
31.30 MAX DOOR OPENING
45.44
(L3)
37.57
(L2)
29.62
(L1)
109 MAX
DOOR SWING
16.69
(GND)
7.87
.71
94 MAX
DOOR SWING
14.82 (23.82)
4.08
94 MAX
DOOR SWING
3.760
2.580
1.400
109 MAX
DOOR SWING
94° MAX
DOOR SWING
23.42 MAX DOOR OPENING
A
VIEW A-A
15