Trane AFDG Installation, Operation And Maintenance Manual page 14

Air-cooled adaptive frequency drive with tracerĀ® adaptiview control
Table of Contents

Advertisement

Drive and Cabinet
Figure 3.
AFDG (remote-mounted) cabinet dimensions: Frame F3, in.
9.10
12.80
3.90
1.85
2.80
120VAC
CONTROL
7.90
1.88
LOW VOLTAGE
WIRING
7.90
1.13
22.61
5.83
2X1 TERMINAL
STRIP
Adaptive Frequency
Drive for Chillers
SERVICE
ACCESS DOOR
10.00
86.81
10.00
39.88 (L3)
69.50
35.34 (L2)
30.80 (L1)
38.00
30.60 MAX
26.80 MIN
(L1-L2-L3)
3.28
17.30
21.020
17.30
18.660
RECOMMENDED
MOUNTING HOLES
1.400
2.580
3.260
3.640
1.280
2.460
3.760
16.340 RECOMMENDED
MOUNTING HOLES
2.580
18.700
1.400
21.060
23.74
NOTES:
1. FAILURE TO REMOUNT CABINET FLOOR GLAND PLATES
WILL HAVE A NEGATIVE INFLUENCE ON THE UNIT'S INTERNAL
COOLING CAPACITY AND CAN CAUSE TRIP FAULTS.
2. MAXIMUM CABLE LENGTH BETWEEN DRIVE AND MOTOR
SHOULD BE 100 FEET OR LESS.
PERMISSIBLE WIRE
3. CUSTOMER PROVIDED LOAD LUGS TO BE CRIMP ON
CONNECTION FOR BOLT ON LUG.
ENTRY AREA
Important:
If wiring to the right-most cabinet, refer to
Danfoss manual BAS-SVX21*-EN (High
power Drive Operating Instructions: TR200)
for special sealing instructions. The gland
plate must be fitted to the frequency
converter to ensure the specified protection
degree, as well as ensuring proper cooling
of the unit. If the gland plate is not mounted,
14
(126.22)
2.80
15.60
TOP VIEW
12X RECOMMENDED LIFTING POINT
23.62
23.62
WARNING LABEL
HAZARDOUS VOLTAGE
CIRCUIT
BREAKER
FRONT VIEW
2.80
18.03
8.48
12.43
3.640
3.640
3.640
3.640
1.280
1.280
1.280
1.280
2.460
2.460
2.460
2.460
16.340 RECOMMENDED
16.340 RECOMMENDED
MOUNTING HOLES
MOUNTING HOLES
18.700
18.700
21.060
21.060
23.62
23.62
(126.22)
BOTTOM VIEW
18.74
( 6.54) CHOKE ID
31.50
22.61
1.13
(8.75)
OUTSIDE OF
BRACKETS
8X MAGETIC CORE CHOKES
11.87
2.05 TYP
6.78
7.87
3.16
18.13
.71
A
14.82
4.08
3.640
3.640
3.640
1.280
1.280
1.280
2.460
2.460
2.460
24.210 RECOMMENDED
3.760
16.340 RECOMMENDED
MOUNTING HOLES
MOUNTING HOLES
26.570
18.700
2.580
28.940
21.060
1.400
31.50
23.74
the frequency converter may trip on
Alarm 69, Pwr. Card Temp.
Units with Ceramic bearings will
not have Common mode Chokes.
AIR FLOW
2.50
13.04 MIN
CLEARANCE
A
2.50
18.86
AIR FLOW
11.73
2X1 TERMINAL STRIP
14.69 (T3)
16.56 (T2)
18.43 (T1)
L1-L2-L3
16.90 MIN / 22.50 MAX
(11.93)
10.10 (GND)
AIR FLOW
AIR FLOW
89.88
89.17
26.58 SERVICE ACCESS DOOR
71.36
23.42 MAX DOOR OPENING
45.44
(T3)
37.57
(T2)
109° MAX
29.62
DOOR SWING
(T1)
16.69
(GND)
94° MAX
DOOR SWING
(23.82)
94° MAX
DOOR SWING
94° MAX
DOOR SWING
31.30 MAX
DOOR OPENING
94° MAX
DOOR SWING
23.42 MAX DOOR OPENING
A
2
.91
VIEW A-A
AFDG-SVU01L-EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afdu

Table of Contents