Scope :
USER MANUAL
DE8-BC Ex d Empty Enclosure
Date:
Ver.:
02.04.2022
3
The passing on and copying of this document and the use or communication of it's contents are forbidden without express authority.
Offenders are liable to payment of damages. All rights are reserved in the event of the registration of a patent .
QA Code:
Checked by:
5
E.T.
Flameproof enclosures
DE8 – BC ...
Approved by:
Page:
S.Gr.
1 of 8
Document no. :
21469

Advertisement

loading

Summary of Contents for Bartec DE8-BC Series

  • Page 1 Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 1 of 8 21469 Flameproof enclosures DE8 – BC … The passing on and copying of this document and the use or communication of it’s contents are forbidden without express authority. Offenders are liable to payment of damages.
  • Page 2 Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 2 of 8 21469 The DE8-BC range of Ex d enclosures are rugged and designed for harsh environment like: •...
  • Page 3 Decrees, orders, laws, directives, circulars, applications, standards, state of art and other documentation relating to its installation site It is forbidden to change anything without the prior written consent of Bartec Technor unless the enclosure undergoes a full Equipment certification at a Notified Body/Certification Body.
  • Page 4: Transport, Storage

    Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 4 of 8 21469 • A defective or abnormal use as well as the non compliance with the instructions of the present document exclude any clause of guarantee and do not engage our responsibility •...
  • Page 5: Technical Features

    Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 5 of 8 21469 below. After torqueing the bolts, check with a shim of 15/100 mm (4/100mm for IIB + H2) all around the flame path that the shim cannot penetrate the enclosure.
  • Page 6 Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 6 of 8 21469 Recommended tightening torques of the Lid bolts Recommended tightening Minimum tensile strength of lid bolts Bolts quantity torque Ma for lubricated bolts [N/mm...
  • Page 7 Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 7 of 8 21469 Number of cable entries: • Any type of cable or conduit entry device certified Ex d can be used and installed according to EN / IEC 60079-14 •...
  • Page 8 Scope : USER MANUAL DE8-BC Ex d Empty Enclosure Date: Ver.: QA Code: Checked by: Approved by: Page: Document no. : 02.04.2022 E.T. S.Gr. 8 of 8 21469 Specific Conditions of use (X): The screws used for the assembly of the various parts of flameproof enclosures must be of yieldstress higher or equal to 700N/mm and according to the tables above for the Lid bolts.

This manual is also suitable for:

De8bc 32De8bc 32dDe8bc 351De8bc 351dDe8bc 43De8bc 43d ... Show all