Cold location controller for top-hat rail installation with extended operating modes for 4 cold loca-
1 CRC-BL-EEV
Cold location controller for top-hat rail installation with extended operating modes
for 4 cold locations or 2 control circuits with EEV
1.1

Front view

Fig. 1: Front view
1.2

Features

Suitable for 4 cold locations max.
Up to 2 electronic expansion valves possible by expansion module
Basic functional sequences and parameters preprogrammed by selection of cold location type
Intelligent fan control, compressor oscillation protection, fan delay
Thermal fan control and draining time after defrosting
Suitable for electric defrost, forced air defrost, hot gas defrost and cool gas defrost
Defrost control by real-time clock with power reserve
Simple defrost synchronisation of multiple controllers (master-slave)
6 defrost times by integrated weekly timer
Digital inputs for setpoint switchover, manual defrost initiation and door contact
Option to select 3-point control
Control sensor weighting can be set separately for day operation and night operation
Support for higher baud rates on the C-BUS
Can be locked to prevent unwanted parameter adjustment
Plain text name for each parameter on the display, language selectable
Unique parameter identification with Quicklinks
1-finger operation
Connection of max. 2 external displays
Plug-in screw terminals
Large data memory for temperature history
Connection to the Wurm system via Wurm CAN communication bus (C-BUS) and
FRIGODATA XP
CRC-BL-EEV_V2.2.0_PI_2020-04B_EN
Sous réserve de modifications techniques
CRC-BL-EEV
tions or 2 control circuits with EEV
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRC-BL-EEV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WURM CRC-BL-EEV

  • Page 1 1-finger operation • Connection of max. 2 external displays • Plug-in screw terminals • Large data memory for temperature history • Connection to the Wurm system via Wurm CAN communication bus (C-BUS) and FRIGODATA XP CRC-BL-EEV_V2.2.0_PI_2020-04B_EN Sous réserve de modifications techniques...
  • Page 2 Wurm GmbH & Co. KG Elektronische Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device if the product is sold.
  • Page 3 Any versions not listed are special solutions for individual projects and are not described in detail in this document. This document automatically ceases to be valid if a new technical description is issued. Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid You can find more information on our website at www.wurm.de.
  • Page 4 CRC-BL-EEV Cold location controller for top-hat rail installation with extended operating modes for 4 cold loca- tions or 2 control circuits with EEV Installing the device This device is designed for top-hat rail installation. The housing has standard dimensions according to DIN 43880 and is also suitable for operation in fuse boxes and distribution cabinets.

Table of Contents