Features

 Suitable for all cold location types, such as cold rooms and refrigeration units
Suitable for propane in accordance with EN 60079-15
 Superheating and constant temperature control in combination with separate EEV module
 Connection for 3 temperature sensors (supply air, return air and limit sensor)
 Weighting of 2 control sensors
 2nd setpoint and independent day / night changeover
 Input for door contact switch with adjustable timed interruption of cooling
 Shock freeze function
 Forced air, electric, hot or cool gas defrost
 Synchronised defrost of several cold location controllers
 Defrosting over fixed times or cyclical interval
 Thermostatic fan control
 Run-up, run-down function of the fan control
 Mode-dependent fan control through analogue output with adjustable speeds
 Oscillation protection and runtime monitoring
 Compressor protection activated through digital input
 3-point control, e.g. for heating function
 Temperature control with external frequency converter (FC)
 Built-in real-time clock with power reserve
 Large data memory for temperature list
 Quick installation
 Direct connection of a CAN-USB to the service socket
 Connection to the Wurm system via a communication bus (CAN bus) and FRIGODATA XP
CRDP-XP_V3.9.6_PI_2018-08_EN
Cold location controller for installation in refrigeration units or
Subject to technical modifications
CRDP-XP
control cabinet doors
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRDP-XP and is the answer not in the manual?

Questions and answers

Summary of Contents for WURM CRDP-XP

  • Page 1  Large data memory for temperature list  Quick installation  Direct connection of a CAN-USB to the service socket  Connection to the Wurm system via a communication bus (CAN bus) and FRIGODATA XP CRDP-XP_V3.9.6_PI_2018-08_EN Subject to technical modifications...
  • Page 2 Wurm GmbH & Co. KG Elektronische Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device if the product is sold.
  • Page 3 CRDP-XP Cold location controller for installation in refrigeration units or control cabinet doors Circuit diagram Installing WARNING Danger to life from electric shock and/or fire!  Switch off the power to the entire plant before installing! Otherwise a mains voltage...
  • Page 4 Cold location controller for installation in refrigeration units or control cabinet doors CRDP-XP installation The CRDP-XP controller is mounted in the refrigeration unit or control cabinet door. 1. Attach the frame clips on the left and right of the installation frame wall.

Table of Contents