RL1 (10A) relay output becomes active when information comes from SW1 input
while the device is on. The relay continues to give an output for the selected time
value. When information comes from SW2 input or STOP button is pressed, the
relay stops giving output directly.
If P4 stage is selected while the device is on, RL1 gives an
output for a preset of 40 seconds. Press
change the duration of P4 step.
Hold
buttons to change. For registration keep
button pressed .
If P5 stage is selected while the device is on, RL1 gives an
output for a preset of 50 seconds. Press
change the duration of P5 step.
Hold
buttons to change. For registration keep
button pressed .
If P6 stage is selected while the device is on, RL1 gives an
output for a preset of 60 seconds. Press
change the duration of P6 step.
Hold
buttons to change. For registration keep
button pressed .
To Change the predetermined times, press the button
And to change time set use
For recording keep
If the STOP button is pressed while the device is running, the
relay stops giving an output.
It is used for turning the device on and off.