ALPHA LITE A-PLUS Series User Manual Book
Hide thumbs Also See for A-PLUS Series:

Advertisement

Quick Links

ALPHA LITE
ALPHA LITE
USER MANUAL
USER MANUAL
BOOK
BOOK
A - P L U S S E R I E S
A 8 - P L U S
A 8 - P L U S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A-PLUS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ALPHA LITE A-PLUS Series

  • Page 1 ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK A - P L U S S E R I E S A 8 - P L U S A 8 - P L U S...
  • Page 2 Product name. Product name. A8-PLUS A8-PLUS Precautions 〔 WARNING 〕 Do not open or disassemble the cover to reduce the risk of electric shock. Please wear safety equipment such as safety helmet during work. Be sure to fix the safety chain on the product when installing and moving. Please install the signs below for people to bypass when install the product on high truss.
  • Page 3: Fixture Information

    ALPHA LITE ┃ USER MANUAL BOOK C o n t e n t s Safety Information Fixture Information Extra Function Sleep Mode Function Fixture Information Fixture Exterior View RDM Function Dimming Speed Setup Dimensions Accessory Options Master Function Fixture ID Number Setup...
  • Page 4 Product name. Product name. A8-PLUS A8-PLUS Product name. A8-PLUS ⇒ Flat light source lighting fixture, which is mainly used in broadcast studio ⇒ Excellent light quality, and average CRI 95~98 / R9, R12 are CRI 90 or higher ⇒ Light that does not expose the light source, with less glare, evenly and extremely soft light distribution ⇒...
  • Page 5: Fixture Exterior View

    ALPHA LITE ┃ USER MANUAL BOOK Fixture Exterior View Barndoor Clamp Yoke Fixed Knob Connector Panel Smart Touch LCD Screen Handle...
  • Page 6 Product name. A8-PLUS Dimensions...
  • Page 7: Accessory Options

    ALPHA LITE ┃ USER MANUAL BOOK Accessory Options Pole operation yoke · Pan & Tilt Soft box · Detachable Honeycomb · Detachable...
  • Page 8: Technical Specifications

    Product name. A8-PLUS Technical Specifications 0.5W 3030 PKG LED / 0.5W RGB 5050 PKG LED LED Chip Type 50,000 Estimated LED Lifetime (hours) 2,500~10,000 (VCT) White Light (K) Full RGB+W (4Color Gamut with Hue and Saturation Control) Full Color Light CRI 97 / TLCI 97 Color Rendition (%) 0~100 (16-bit)
  • Page 9 ALPHA LITE ┃ USER MANUAL BOOK Photometry Data Distance(m) 5600K 5600K Illuminance(lux) 135° 1040...
  • Page 10: Power Connection

    3. If the operating voltage is out of the proper voltage range, SMPS function may be degraded or damaged. Power Pass-Thru : Based on operating voltage 240V and using the cable provided by ALPHA LITE. Start <Connect 01> <Connect 02>...
  • Page 11: Dmx Connection

    ALPHA LITE ┃ USER MANUAL BOOK DMX Connection 3-pin or 5-pin XLR sockets are equipped for DMX input and output, depending on user needs. Connect the controller to a lighting, or lighting fixture to other lighting fixture. If user uses a standard DMX controller, the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain.
  • Page 12 Product name. A8-PLUS Unlocking When the fixture is turned on, the Smart Touch screen automatically locked. To unlock the touch screen, touch the finger icon( ) three times. If you do not touch for 30 seconds, the lock is reset. 〔...
  • Page 13 ALPHA LITE ┃ USER MANUAL BOOK Screen Instructions 〔 Main Screen (Unlocked) 〕 〔 Setting Screen 〕 Display DMX MODE or USER MODE or COLOR MODE. Current Mode The current temperature of the instrument is detected and Fixture Current Temperature displayed in °C.
  • Page 14 Product name. A8-PLUS Menu Tree [ Main screen ] Home DMX512 Mode DMX mode select DMX address input Information DMX channel value User Mode Intensity setup Color temperature setup Tint setup Information Description of each function Color Mode RGB color setup Saturation setup White setup Full screen...
  • Page 15: Product Information

    ALPHA LITE ┃ USER MANUAL BOOK Main Screen by Mode & Product Information Main Screen by Mode Information HOME DMX MODE USER MODE COLOR MODE The current mode is displayed in the upper left corner of the main screen among DMX mode, user mode and color mode, and the DMX address number of the equipment is displayed in the middle with a yellow number.
  • Page 16: Dmx Mode

    Product name. A8-PLUS DMX Mode Channel Change & Address Setup DMX MODE : It is used to adjust value by DMX512 signal. HOME DMX512 MODE Move to the DMX channel change screen. In DMX512 MODE screen, user can select DMX channel mode on top tap. Input DMX512 address by pressing the number pad.
  • Page 17: User Mode

    ALPHA LITE ┃ USER MANUAL BOOK User Mode Setup & Intensity / CCT / Tint Adjust USER MODE : It is used when the user directly manipulates the equipment. HOME USER MODE Move to user-operable screen to change Intensity/CCT/Tint. Activate control bar and adjust value directly 'Current Intensity' according to selected function.
  • Page 18: Color Mode

    Product name. A8-PLUS Color Mode Setup & RGB / Hue / Saturation / White Adjust COLOR MODE : It is used when the user directly manipulates the equipment. HOME COLOR MODE Move to user-operable screen to change Hue/Saturation. COLOR MODE screen Touch the function you want to change Active in Orange ▶...
  • Page 19: Extra Function

    ALPHA LITE ┃ USER MANUAL BOOK Extra Function – Sleep Mode / Master / RDM / Dimming Speed Move to additional settings other than the main icon. HOME SETTING SETTING screen Touch ON/OFF the function you want to change among SLEEP ▶...
  • Page 20: Master Setup

    Product name. A8-PLUS Extra Function – Sleep Mode / Master / RDM / Dimming Speed Master Setup The master slave function allows to synchronize and control all connected lighting • fixtures through the DMX signal without a console connection. If a problem occurs in the console or communication line, it is possible to control •...
  • Page 21 ALPHA LITE ┃ USER MANUAL BOOK Fixture ID & Label Setup Move to fixture management number setting screen. HOME FIXTURE ID Move to input screen that can change the number Input the desired number 001 to ▶ 9999 and press Enter Move to the FIXTURE ID screen that displays the large size ▶...
  • Page 22: Error Information

    Product name. A8-PLUS Error Information Temperature Sensor Detects the temperature of the current fixture(LED source, housing) and displays it on the Smart Touch LCD screen. If the temperature If it exceeds exceeds 45˚C 46~69˚C 70˚C 85˚C 75˚C or less is cyan is yellow or more is red the actual LED...
  • Page 23: Cross Fader

    ALPHA LITE ┃ USER MANUAL BOOK Cross Fader & Color Macro Cross Fader [In 5 or 8 channel mode] - When the DMX value of Ch.4(Cross Fader) is 0, the color temperature set by Ch.2(CCT) is distributed. - When the DMX value of Ch.4 is 255, only color set by Ch.5(Color Macro in 5 Channel Mode) or Ch.5~8(Red, Green, Blue and White in 8 Channel Mode) is distributed.
  • Page 24: Dmx Protocols

    Product name. A8-PLUS DMX Protocols (1/4) Channel Mode Mode Channel DMX Value Function 0~255 0~100 Dimmer Mode Channel DMX Value Function 0~255 0~100 Dimmer Color Temperature 0~255 0~100 (CCT) See DMX 0~119 / 120~255 Tint Protocols (3) Mode Channel DMX Value Function 0~255 0~100...
  • Page 25 ALPHA LITE ┃ USER MANUAL BOOK DMX Protocols (2/4) 3 & 5 & 8 Channel mode : Color Temperature Function Function Function Function Function Value Value Value Value Value 2500 4000 5500 5500 5500 204~205 51~52 102~103 153~154 5550 2550...
  • Page 26 Product name. A8-PLUS DMX Protocols (3/4) 3 & 5 & 8 Channel Mode : Color Macro DMX Value Color Value Color Macro DMX Value Color Value Color Macro 1 - 6 131 - 134 7 - 12 135 - 138 13 - 18 139 - 142 19 - 24...
  • Page 27 ALPHA LITE ┃ USER MANUAL BOOK DMX Protocols (4/4) 3 & 5 & 8 Channel mode : Tint [ Tint ] Mode DMX Value Output Value Function 0~10 No Effect 11~20 (-)1.00 Full Magenta 21~119 (-)0.99 ~ (-)0.01 99~1% Magenta...
  • Page 28 (Example) Setting Model number Device Model Description A8-PLUS Disable of the device Name of the Manufacturer Label ALPHA LITE Disable manufacturer ex) Input : BASE123 · Name : BASE123 · Management # : 123 Fixture name and Device Label BASE123...
  • Page 29 ALPHA LITE ┃ USER MANUAL BOOK RDM Protocols (3/3) [ Sensor ] Value Device Sensors Description User Setting Remarks (Example) Current fixture Sensor Temp 64℃ Disable temperature [ Error Message ] Condition Level Description Display Sensor Over Temp Warning Fixture temperature 46 ~ 69˚C...
  • Page 30 ALPHA LITE USER MANUAL BOOK 82-2-6317-0464 <Tel > 82-2-2039-0464 <Fax> hello@alpha-lite.net <E-mail> www.alpha-lite.net <Web> 2-4 Floor, 5-8, Gyeongin-ro 88-gil,Yeongdeungpo-gu,Seoul,Republic of Korea, 07363...

This manual is also suitable for:

A8-plus

Table of Contents