Page 1
ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK A S E R I E S A 2 4 4 0 A 2 4 4 0...
Page 2
Product name. Product name. A2440 A2440 Precautions 〔 WARNING 〕 Do not open or disassemble the cover to reduce the risk of electric shock. Please wear safety equipment such as safety helmet during work. Be sure to fix the safety chain on the product when installing and moving. Please install the signs below for people to bypass when install the product on high truss.
ALPHA LITE ┃ USER MANUAL BOOK C o n t e n t s Safety Information Fixture Information Extra Function Sleep Mode Function Fixture Information Fixture Exterior View RDM Function Dimming Speed Setup Dimensions Accessory Options Master Function Fixture ID Number Setup...
Page 4
Product name. Product name. A2440 A2440 Product name. A2440 ⇒ Flat light source lighting fixture, which is mainly used in broadcast studio, can create a variety of atmospheres in the set. ⇒ Excellent light quality, and average CRI 95~98 / R9, R12 are CRI 90 or higher ⇒...
3. If the operating voltage is out of the proper voltage range, SMPS function may be degraded or damaged. Power Pass-Thru : Based on operating voltage 240V and using the cable provided by ALPHA LITE. Start <Connect 01> <Connect 02>...
ALPHA LITE ┃ USER MANUAL BOOK DMX Connection 3-pin or 5-pin XLR sockets are equipped for DMX input and output, depending on user needs. Connect the controller to a lighting, or lighting fixture to other lighting fixture. If user uses a standard DMX controller, the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain.
Page 12
Product name. A2440 Unlocking When the fixture is turned on, the Smart Touch screen automatically locked. To unlock the touch screen, touch the finger icon( ) three times. If you do not touch for 30 seconds, the lock is reset. 〔...
Page 13
ALPHA LITE ┃ USER MANUAL BOOK Screen Instructions 〔 Main Screen (Unlocked) 〕 〔 Setting Screen 〕 Display DMX MODE or USER MODE or COLOR MODE. Current Mode Display current channel mode. *Only display on DMX MODE Current Channel Mode Display current DMX512 Address.
Page 14
Product name. A2440 Menu Tree [ Main screen ] Home DMX512 Mode DMX mode select DMX address input Information DMX channel value User Mode Intensity setup Color temperature setup No applicable model Tint setup Information Description of each function No applicable model Color Mode RGB color setup Saturation setup...
ALPHA LITE ┃ USER MANUAL BOOK Main Screen by Mode & Product Information Main Screen by Mode Information HOME DMX MODE USER MODE COLOR MODE The current mode is displayed in the upper left corner of the main screen among DMX MODE,...
Product name. A2440 DMX Mode Channel Change & Address Setup DMX MODE : It is used to adjust value by DMX512 signal. HOME DMX512 MODE Move to the DMX channel change screen. In DMX512 MODE screen, user can select DMX channel mode on top tap. Input DMX512 address by pressing the number pad.
Page 17
ALPHA LITE ┃ USER MANUAL BOOK User Mode Setup & Intensity / CCT Adjust * If the equipment does not support COLOR MODE, the Tint function does not work. USER MODE : It is used when the user directly manipulates the equipment.
Product name. A2440 Extra Function – Sleep Mode / Master / RDM / Dimming Speed Move to additional settings other than the main icon. HOME SETTING SETTING screen Touch ON/OFF the function you want to change among SLEEP ▶ MODE, MASTER, and RDM MODE Active in Orange Set ON/OFF’...
ALPHA LITE ┃ USER MANUAL BOOK Extra Function – Sleep Mode / Master / RDM / Dimming Speed Master Setup The master slave function allows to synchronize and control all connected lighting • fixtures through the DMX signal without a console connection.
Page 20
Product name. A2440 Fixture ID & Label Setup Move to fixture management number setting screen. HOME FIXTURE ID Move to input screen that can change the number Input the desired number 001 to ▶ 9999 and press Enter Move to the FIXTURE ID screen that displays the large size ▶...
ALPHA LITE ┃ USER MANUAL BOOK Error Information Temperature Sensor Detects the temperature of the current fixture(LED source, housing) and displays it on the Smart Touch LCD screen. If the temperature If it exceeds exceeds 45˚C 46~69˚C 70˚C 85˚C 75˚C...
Product name. A2440 DMX Protocols (1/2) Channel Mode [ Channel mode of the basic model ] Mode Channel DMX Value Function 0~255 0~100 Dimmer Mode Channel DMX Value Function 0~255 0~100 Dimmer Color 0~255 0~100 Temperature(CCT)
Page 23
ALPHA LITE ┃ USER MANUAL BOOK DMX Protocols (2/2) Channel 2 : White Color Temperature DMX Value Function DMX Value Function DMX Value Function Dimmer 0~100% 4350K 5850K 0~255 116~119 236~239 2900K 4400K 5900K 120~123 240~243 2950K 4450K 5950K 124~127...
Page 25
ALPHA LITE ┃ USER MANUAL BOOK RDM Protocols (2/3) Value User Device Property Description Remarks (Example) Setting Model number Device Model Description A2440 Disable of the device Name of the Manufacturer Label ALPHA LITE Disable manufacturer ex) Input : BASE123 ·...
Page 26
Product name. A2440 RDM Protocols (3/3) [ Sensor ] Value Device Sensors Description User Setting Remarks (Example) Current fixture Sensor Temp 64℃ Disable temperature [ Error Message ] Condition Level Description Display Sensor Over Temp Warning Fixture temperature 46 ~ 69˚C Orange message Sensor Over Temp Error...
Page 27
ALPHA LITE USER MANUAL BOOK 82-2-6317-0464 <Tel > 82-2-2039-0464 <Fax> hello@alpha-lite.net <E-mail> www.alpha-lite.net <Web> 2-4 Floor, 5-8, Gyeongin-ro 88-gil,Yeongdeungpo-gu,Seoul,Republic of Korea, 07363...