Adjust Menu (1 of 2) *for installer use only
Press
+
+
Together
Display
Continued on next page.
© 2008
D 540e - 02/08
These settings are intended for use by the installer only and are
not required for use by average users of the thermostat.
• • Press and release the Mode,
• • Press and release the Mode button to go to the next
setting.
• • Once all settings are complete, wait 20 seconds for the
Range
40 to 85°F
(4.5 to 29.5°C)
SET ROOM HEAT
Default = 70°F
Set the room heating temperature while in the
(21.0°C)
40 to 85°F
(4.5 to 29.5°C)
SET ROOM HEAT
Default = 65°F
Set the room heating temperature while in the
(18.5°C)
40 to 85°F
(4.5 to 29.5°C)
SET ROOM HEAT AWAY
Default = 62°F
Set the room heating temperature while in the Away scene.
(16.5°C)
40 to 85°F
(4.5 to 29.5°C)
SET ROOM COOL
Default = 78°F
Set the room cooling temperature while in the
(25.5°C)
40 to 85°F
(4.5 to 29.5°C)
SET ROOM COOL
Default = 85°F
Set the room cooling temperature while in the
(29.5°C)
40 to 85°F
(4.5 to 29.5°C)
SET ROOM COOL AWAY
Default = 85°F
Set the room cooling temperature while in the Away scene.
(29.5°C)
FAN MODE
1 or 2
Select if the fan should operate with cooling (Fan Mode 1), or
Default = 1
with the heating and cooling (Fan Mode 2).
OFF, On
VENTILATION
Default = OFF
Select whether or not ventilation is required.
FAN
Auto, 10 to 90%,
Set the minimum percentage the fan should operate while in
On
the
Default = Auto
Available when:
• • Ventilation is set to On.
6 of 12
thermostat to return to normal operation.
Description
event. This provides ventilation for the building.
, and
buttons together.
event.
event.
event.
event.

Advertisement