General Remarks

Items included in the Shipment

The system was prestaged, tested and programmed in the factory with all components.
System start-up and the function checks required should be performed in accordance with
Start-up Instructions, RXL2-120.034.01.
The system is operational once installation and start-up have been completed.
The system is shipped in the following sections:
LITHOSTAR Multiline - basic unit.
Generator power unit cabinet, equipped with components and boards.
H1 HF high voltage transformer.
Two standard cabinets.
Control console.
Accessories/cover panels.

Requirements

- The preinstallation work steps must have been completed in accordance with Planning
Guide (PG) RXL2-120.021.01.
- Prior to the installation, the power line connection must be completed and provided
with a system breaker, an emergency OFF switch, and ground fault detector as
specified in the Planning Guide (PG) RXL2-120.021.01.
- The hardware for mounting the unit to the floor (Liebig expansion bolts /mounting plate)
must be installed per Installation Instructions RXL2-120.038.01...
- The condition of the access route within the building, as well as the condition of the
room in which the unit is to be installed, must be in compliance with the project
drawings and the data listed under the "General Installation and Conditions of
Shipment - Med. Technology Division".

Text Emphasis

"Cautions" are information provided with special emphasis when there is the potential
for damage to the equipment.
"Notices" are information provided with special emphasis to facilitate proper use of the
equipment or proper execution of a procedure.
All texts referring to adjustments or installation steps marked with symbol"
be confirmed by the subcontractor or the Siemens engineer in the installation protocol
(register 3 of logbook).

Replacement of damaged or Lost Screws

Damaged or lost screws may be replaced only with steel screws which meet the
requirements of DIN 267 and must be rated in the specified hardness class.
All Allen screws used must be classified as hardness class 8.8.