4.
Recoil Starter
Place the unit on a flat, clear area.
Firmly grasp throttle handle with
left hand and rapidly pull recoil
starter handle/rope (E) until
engine fires.
Recoil starter: Use short pulls - only 1/2 ~ 2/3 of rope for starting. Do
not allow the rope to snap back in. Always hold the unit firmly.
Note: If engine does not start after 5 pulls, use Cold Start
Procedure.

Stopping Engine

1.
Throttle Trigger/Throttle Position
Lever
Release throttle trigger (F). Move
throttle position lever (B) forward
to idle position and allow engine to
return to idle before shutting off
engine.
2.
Stop Switch
Move stop switch (A) to STOP
position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using unit
again.