Introduction
This installation guide shows how to install the T4 touchscreen power
box (sometimes called the "mid-box"). The power box is the physical
interface between the touch screen and the wall box.
See other installation guides:
• Wall box for new construction:
• Wall box for retrofit:
ctrl4.co/wallbox-retro
ctrl4.co/t4-inwall-ig
• T4 POE installation guide:
• T4 AC installation guide:
ctrl4.co/t4ac-ig
Box contents
• Power box (to power the T4 touchscreen)
• Two screws (to attach the power box to the wall box)
• Four screws (to attach to standard double-gang box)
• Two wire nuts (AC model only)
Accessories available for purchase
• Pakedge 802.3at/af Gigabit PoE+ Injector (PI-30AT), or Araknis
Networks Gigabit PoE+ Injector
(AN-ACC-INJ-POE-30W), each sold separately.
• Wall box options (sold separately)—Metal and plastic, for new
construction or retrofit installations.
• In-Wall Touchscreen Wall Box Kits - New Construction
• Plastic (C4-NWB57C-P)
• Metal (C4-NWB57C-M)
• In-Wall Touchscreen Wall Box Kits - Retrofit
• Plastic (C4-RWB57C-P)
• Metal (C4-RWB57C-M)
• Third-party products:
• Arlington™ Double Gang Non-Metallic Box - 4 x 4
(FSR404BL)
Wall-box requirements
• Standard 2-gang wall box with a minimum depth of 42 mm (1.65")
and a minimum internal volume of 410 cm
• Wall box must be certified by a NRTL and be UL listed to QCMZ or
QCIT category
1 1
ctrl4.co/wallbox-new
(25 in
)
3
3
Warnings
Warning! Install in accordance with all national, state, and
local electrical codes.
AVERTISSEMENT ! Installez selon tous les national, état, et
codes électriques locaux.
Warning! This product generates heat. The room must
have adequate ventilation or the ability to dissipate heat
effectively.
AVERTISSEMENT ! Ce produit produit de la chaleur. La
salle doit avoir à ventilation proportionnée ou la capacité
d'absorber la chaleur efficacement.
Warning! Use this product only in dry locations.
AVERTISSEMENT ! Employez ce produit seulement dans des
endroits secs.
Caution! Improper use or installation can cause DAMAGE OF
PROPERTY.
AVERTISSEMENT ! L'utilisation ou l'installation inexacte peut
causer DAMAGE DE PROPRIÉTÉ.
Important! Using this product in a manner other than outlined
in this document voids your warranty. Further, Control4 is
NOT liable for any damage incurred with the misuse of this
product. Visit
snapone.com/legal
Important ! Utilisant ce produit en quelque sorte autre
que décrit dans ce document vide votre garantie. De plus,
Control4 n'est pas responsable d'aucun dommage encouru
avec l'abus de ce produit. Visitez
plus d'informations.
Specifications
Model Numbers
C4-T4IWMB-AC or C4-T4IWMB-POE
Ethernet or Wi-Fi
• 802.11b/g/n 2.4 GHz
• 802.11a/n/ac 5 GHz
• Security: WEP, WPA/WPA2 PSK, 802.1x EAP, PEAP
Notes: (1) While technically the touchscreen can
Network
use 802.11b, 802.11b is not supported. (2) 802.11n is
recommended for best performance. Even with 802.11n,
broadcasting to several devices will degrade Video
Intercom response time and images. Broadcasting to
additional devices will further degrade performance. See
"Wireless Network Limitations."
PoE: 13W peak (IEEE 802.3af)
Power supply
AC: 100-240VAC
AC box output: 5V DC 7.5W rms (10W peak)
Dimensions (W × H × D)
127 × 119 × 45 mm (5.0 × 4.67 × 1.77")
Weight
0.13 kg (0.29 lb)
Operating temperature
0 to 40 ˚C (32 to 104 ˚F)
Storage temperature
-20 to 70 ˚C (-4 to 158 ˚F)
for more information.
snapone.com/legal
pour

Advertisement

loading

Summary of Contents for Control 4 T4 Series

  • Page 1 8" and 10" T4 Series In-Wall Touchscreen Power Box Installation Guide Supported models Warnings • C4-T4IW8-POE 8" T4 In-Wall PoE Touchscreen Power Box Warning! Install in accordance with all national, state, and local electrical codes. • C4-T4IW10-POE 10" T4 In-Wall PoE Touchscreen Power Box AVERTISSEMENT ! Installez selon tous les national, état, et...
  • Page 2 Installation Requirements Important! Before you can complete the instructions below, Network you must have an 8" or 10" Touchscreen wall box installed according to the documentation provided in the wall box kit. • If using Ethernet: Ethernet network installed and available that See “Accessories”...
  • Page 3 Option 3: Wi-Fi with AC power Figure 3: Insert Ethernet cable into power box To connect AC power: 1 Place the touchscreen above a power source, for example, an outlet. Make sure the location is within distance of your Wi-Fi signal.
  • Page 4 Attach the power box and touchscreen Additional resources To install the power box into the wall box: The following resources are available for additional support. 1 Align and bend the wires to fit them inside the wall box. • Knowledgebase and forums in Technician Community: tech.control4.com 2 Slide the power box into the wall box, then secure the power box •...

This manual is also suitable for:

C4-t4iw8-poeC4-t4iw10-poeC4-t4iw8-acC4-t4iw10-ac