  • Page 1 Software Manual Control Panel for Pegasus Units Models: MD421-P MD422-P BWP4-P Software Manual V. 5.02...
  • Page 2: Table Of Contents

    1. DESCRIPTION 2. DISPLAY LAYOUT 3. MODES 3.1 Power On 3.2 Standby 3.3 Power off 3.4 Error / Warning 4. CONTENT OF MAIN- AND SUBMENUS 5. OVERVIEW OF MAIN- AND SUB-MENUS 5.1 Content of the Info menu 5.2 Content of the Errors menu – CAUSE & REMEDY 5.2.1 Error List 5.3 Content of the Setup menu 5.3.1 Submenu setting...
  • Page 3: Description

    1. Description This software manual describes the operation of the control panel of the Single Booster unit. The unit is operated via the control panel (see below illustration). 1. OFF Button (1) switches OFF the unit. 2. ON/STANDBY Button (2) switches ON the unit. 3.
  • Page 4: Display Layout

    2. Display layout Example: Standard Standard pressure: 25 bar pressure: 25 bar When switched on the display will show an arrow symbol in the top right corner equivalent to the active navigation buttons on the control board. The arrows illustrate that it is possible to scroll up and down between the menus. Scrolling to the right makes it possible to enter a value.
  • Page 5: Modes

    3. Modes 3.1 Power On The very first time the unit is switched on, we recommend setting date and time in the Setup menu, settings, display EP. If date and time is not set, date and time will count from the pre-set default date and time. Date & time 2006-01-01 12:00 Set date and time using navigation buttons . Set date & time 2006-01-01 12:00 Confirm by pressing OK button. 3.2 Standby The start up display will look as the one below. Nilfisk FOOD Pegasus...
  • Page 6: Power Off

    3.3 Power Off When the unit is off the display will only show a small dot in the top right corner. In Off mode it is possible to access all menus without the pump running by pressing the OK button on the panel. Dot is equivalent to the OK confirm button on the panel. 3.4 Error/Warning ERROR WARNING In case of an error, “ ERROR” will appear on the display screen. Press the OFF button to switch of unit. If the error remains when the unit is switched ON again, please Press right arrow to see current error. In case of a warning, “WARNING” will appear on the display screen. When a warning is detected the machine will either stop or run with limited performance until the cause of the warning has been improved (eg.
  • Page 7: Content Of Main- And Submenus

    4. Content of Main- and Submenus The control panel contains the below main menu screen displays. Scroll between the menus using the navigation buttons. Each main menu contains submenus which will be described subsequently. Info Errors Setup Readings 110007944-EN Software Manual_Pegasus.
  • Page 8: Overview Of Main- And Sub-Menus

    5. Overview of Main- and Sub-menus 1. Info (A) 1 Info (AEA) 2. Errors (B) 3. Setup (C) (default password 6802) 1 Password (CA) 2 Settings (E) Standard pressure (ER) Auto off delay (EZ) Date & Time (EP) 3 Languages & units (F) Language (FA) Units (FB) 4 Communication (I)
  • Page 9: Content Of The Info Menu

    5.1 Content of the Info menu Please note that the Info menu is only for display – all data must be typed in via the setup menu! INFO SW ID: 5.02 5-14 Info HW ID:PEGASUS CT ID: 1.01 This display view is only ment as an example, SW ID and CT ID shows the current SW version. Displays Software version and Pump size, machine configuration and controller software version/ID.
  • Page 10 1. Press “off” button C6 Low Sensor 1. Voltage supply for sensors too low 2. If error reoccurs, contact your local Supply Voltage service technician. C7 No Response 1. No communication between display and control 1. Contact your local service technician. Error board 1. Insufficient water supply C8 Low Tank 1. Check correct water supply 2. Secure suffcient air supply to valve Level 2.
  • Page 11: Content Of The Setup Menu

    1. Signal from block sensor, out of range 1. Press “off” button C34 High Sensor 2. If error reoccurs, contact your local Signal block service technician. 1. Signal from flow sensor, out of range 1. Press “off” button C35 High Sensor Signal flow 2. If error reoccurs, contact your local service technician. 1. Press “off” button C40 Sensor Load 1. Supply voltage for pumptop sensor too low. 2. If error reoccurs, contact your local Pumptop Sensor 2. Pumptop sensor using too much current service technician.
  • Page 12: Submenu Setting

    5.3.1 Submenu setting Standard Standard Settings pressure: 25 bar pressure: 25 bar Autooff Set auto off Delay:OFF Delay: OFF Set date & time Date & time 2006-01-01 12:00 2006-01-01 12:00 Set date and time 5.3.2 Submenu Language & Units Language: Languages &...
  • Page 13: Content Of Readings

    5.4 Content of Readings Readings Pump state 82Hz Outlet pres . 24 bar Water temp. 29 °C Supply pressure 2.5 bar Flow status No Flow 110007944-EN Software Manual_Pegasus.
  • Page 14: Upgrade Firmware

    6. Upgrade Firmware Upgrading from software version 4.10 or higher 6.1 Upgrade using USB Cable Connect USB cable (Item No. 110007947) to PC USB port (Remove other USB cables connected to PC) Connect Display cable to USB cable In the menu go to, Setup->”password”->Communication-> Firmware upgrade by cable- >Confirm Firmware upgrade and press “OK” Display should now be looking like this: Upgrade Ready Power Cycle and...
  • Page 15 Press UPGRADE button in FWU 200 tool 14. After a short while the FWU tool should start upgrading, the upgrade button should turn Yellow and change to “RUNNING” 15. The progress bar “Program” must go to the end before the upgrade is complete (less than 1 minute) 16. When the upgrade is complete the FWU tool should be looking like this, Button turns Green and text changes to “DONE/NEW” Now the display is upgraded 18. To verify software version in display, in the menu go to, Info->Machine info 19. Here you will find display software version and control software version. SW ID “Display software”, HW ID “type of device”, CT ID Controller board software(if display is not connected to a control board, control software will be 0/300) 110007944-EN Software Manual_Pegasus.
  • Page 16: Upgrade Using Irda Cable

    6.2 Upgrade using IrDA Cable Connect power to equipment In the menu go to, Setup->”password”->Communication-> Firmware upgrade by Infrared- >Confirm Firmware upgrade and press “OK” Display should now be looking like this: Upgrade Ready Power Cycle and Start PC App. Turn Off equipment and turn it on again (Power cycle) Make sure the All three led’s are on (Green “ON”, red “ERROR” and red “OFF”) and the display is blank Connect Irda module (Item No. 110001558) to PC USB port Place Irda module on display module like this Startup PC program FWU200.exe (can be downloaded from Nilfisk Food website) Window should be looking like this...
  • Page 17 12. When the file is located press “Open” in browser window 13. The file name will now be written in file text line Press UPGRADE button in FWU 200 tool 15. After a short while the FWU tool should start upgrading, the upgrade button should turn Yellow and change to “RUNNING” 16. The progress bar “Program” must go to the end before the upgrade is complete (less than 1 minute) 17. When the upgrade is complete the FWU tool should be looking like this, Button turns Green and text changes to “DONE/NEW” Now the display is upgraded 19. To verify software version in display, in the menu go to, Info->Machine info 20. Here you will find display software version and control software version. SW ID “Display software”, HW ID “type of device”, CT ID Controller board software(if display is not connected to a control board, control software will be 0/300) 110007944-EN Software Manual_Pegasus.
  • Page 18: Upgrade Controller Board

    6.3 Upgrade Inverter Power off unit using service switch (wait for unit to discharge approximately 5 min.) Open Inverter box Disconnect the Display cable connected to either of the two modbus terminals Connect the usb cable (110007946) to either one of the modbus connectors Connect usb cable to PC Power on inverter by using service switch (AWARE OF HIGH VOLTAGE IN INVERTER!) Start up Firmware upgrade program (Can be downloaded from Nilfisk FOOD web) Click browse to select upgrade file *.hex (Can be downloaded from Nilfisk FOOD web) Click in Serial port up/down to select the com port for USB cable, if comport is not showing...
  • Page 19 13. Power off unit using service switch (wait for unit to discharge approximately 5 min.) Disconnect the usb cable from inverter Connect the display to modbus connector again Mount the lit of the inverterbox Turn unit back on. 110007944-EN Software Manual_Pegasus.