Tanpera PROWATT User Manual page 10

Electrical water heater panel

Advertisement

To change the voltage hysteresis value, SET button should be pressed. Voltage hist starts to flash
and the value next to it can be changed with up / down keys. After the change is completed, press
SET button to save the value to memory. The up / down buttons are used to find the parameter
we want to change and the parameter is highlighted. Press SET button and the text starts to flash,
this value can be changed.
Parameters and descriptions in the Time Settings menu;
Voltage Hist: Factory set to 5V, no change required.
Voltage On Time: This is the voltage switch-on time setting. It is the waiting time for automatic
reset when the measured voltage values are again within the desired limits whenever the system
is in fault condition due to voltage error.
Voltage Off Time: This is the voltage faulty switch-on time setting. It is the waiting time to switch
off when the measured voltage values are out of the set values. It is necessary to prevent the
motor from switching off frequently in case of instantaneous fluctuations.
Inrush Time: Inrush current time setting. The current cannot be compared with the current set
values during the set period/time.
Temperature Time: When the measured temperature values exceed the set temperature values,
it waits for the time set here and then goes into error status.
Temperature Hist: The system that has failed due to high temperature must fall down to the set
degree for a system restart.
Current Delay: Current fault trip time setting. When the upper or lower current exceeds the set
value, the motor stop time setting is set in seconds.
Vibration Time: If the measured vibration value is above the set vibration value, it waits for the set
time here.
Switching: This is the setting for limiting the number of switches. It is the setting of limiting the
number of times the motor starts and goes out in 1 hour.
9
We reserve the right to make changes in technical information.
Time Settings
Voltage hist =