Tanpera TDB Series Installation, Operation And Maintenance Manual

Tanpera TDB Series Installation, Operation And Maintenance Manual

Storage water heater / domestic hot water storage tank

Advertisement

STORAGE WATER HEATER
TSB and TDB Series
DOMESTIC HOT WATER STORAGE TANK
PRO Series
INSTALLATION, OPERATION AND
MAINTENANCE MANUEL
www.tanpera.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tanpera TDB Series

  • Page 1 STORAGE WATER HEATER TSB and TDB Series DOMESTIC HOT WATER STORAGE TANK PRO Series INSTALLATION, OPERATION AND MAINTENANCE MANUEL www.tanpera.com...
  • Page 2 However, because of rapid developments in this field we cannot be held liable for changes in specifications affecting the contents of this publication. COPYRIGHT Copyright © Tanpera A. Ş. All rights reserved. No part of this publication may be reproduced or distributed without prior written permission of Tanpera A. Ş.
  • Page 3: Table Of Contents

    4. GENERAL 4.1. Identification of the product 4.2. Correct Operation 4.3. Cautions 5. CONSTRUCTION 5.1. TSB, TDB series storage water heater 5.2. PRO series domestic hot water storage tank 6. INSTALLATION 6.1. Siting 6.2. Space requirements for the installation location 6.3.
  • Page 4: Foreword

    2. INTRODUCTION This manuel is applicable for the TSB, TDB series storage water heaters and PRO series hot water storage tanks produced and supplied by TANPERA. TANPERA cannot be held responsible or liable for damage as a result of incorrect installation, use and/or maintenance of TANPERA storage water heater and hot water storage tank as well as not complying with the instructions in this manual.
  • Page 5: General

    4. GENERAL 4.1 Identification of the product All storage water heaters and hot water storage tanks supplied by TANPERA are provided with a name plate. On this plate the following details are specified: • type of product • serial number •...
  • Page 6: Correct Operation

    This manual is of no value if it is not available at the time when your staff needs it. If a problem occurs with your TANPERA water heater and storage tank which is beyond the scope of this manual, do not hasitate to contact us. The installation should not be put into operation before all indistinctnesses have been solved! To avoid injuries and damages, follow the instructions and local applicable safety regulations.
  • Page 7 Damage to equipment can be caused by: • external forces; • corrosion; • chemical action; • erosion; • material exhaustion; • water hammer; • thermal and/or mechanical shock; • freezing; • wrong transport/lifting. The chemical and physical nature of the water to be heated and stored in the tank must comply with the limit values specified in the Council directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption.
  • Page 8: Construction

    Information on the physical structures and dimensions of the storage water heater and hot water storage tank covered by this manual is below. 5.1. TSB, TDB series storage water heater • Capacity: 100 – 3000 liters • Designated use: Hot water not exceeding 90°C •...
  • Page 9: Pro Series Domestic Hot Water Storage Tank

    Double Coil (TDB) Protective anode Thermometer Hot water exit Temperature Heating inlet sensor connection (upper coil) Hot water return Electric coil connection Heating exit (upper coil) Manhole Heating inlet access (lower coil) Heating exit Temperature (lower coil) sensor connection Cold water intake Drain 5.2.
  • Page 10: Installation

    (floor drain, sump pit and pump etc.) capable of discharging water should be provided on the floor. TANPERA shall not be liable for water leak damages that may be caused by the product or the piping, in places where such a measure is not taken.
  • Page 11: Transport, Lifting, Storage

    6.3. Transport, lifting, storage WARNING: To prevent personal injury always use appropriate hoisting equipment. If you are to lift the unit itself or lay it on the ground to remove the pallet, straps should be used. Transporting: The products will be supplied vertically on a pallet.
  • Page 12: Installing The Pipe Connections

    6.4. Installing the pipe connections TANPERA storage water heaters and hot water storage tanks will be provided with internal thread connection ports. When connecting the pipe system to the product make sure that no stress or strain is imposed,...
  • Page 13: Electric Connection

    TANPERA cannot be held responsible for the damages that occur in the products which do not have a properly sized safety valve having the above mentioned qualifications. In order to eliminate the risk of scalding with hot water during use, safety precautions must be taken in the system to prevent the domestic water temperature from exceeding 60°C.
  • Page 14: Commissioning

    TANPERA service are not covered by the warranty. Commissioning of the products not containing electric heater may only be done by staff specially trained for the job. If you wish, these products also can be commissioned by TANPERA service free of charge.
  • Page 15: Maintenance

    8. MAINTENANCE If you wish, TANPERA service can perform cleaning and periodic maintenance of your product. Maintenance and cleaning of the product must only be carried out by authorized, trained and qualified personnel. Before starting maintenance and cleaning operations, the product must be switched off and the water inside must be cooled down below 40°C.
  • Page 16 If no signs of wear are observed on the anode during the control, the anode may not be functioning. In this case, call TANPERA service. Follow the steps below for anode control: Close the cold water inlet valve.
  • Page 17: Problem Solving

    Blockage in the system • Clean the strainer filter at the cold water inlet • Check the anode. Replace if finished Anode is depleted or • Call TANPERA service if the problem is not not functioning Turbid water flowing resolved from taps •...
  • Page 18 Pressure increase Domestic water leakage • Call TANPERA service in the heating circuit into the heating circuit Call TANPERA service for electrical faults of products with electric heater. We reserve the right to make changes in technical information.
  • Page 19: After Sales Service

    (anode, gasket etc.) and for the addition of electric heater. All products that TANPERA has sold are under the guarantee of TANPERA A.Ş. for a period of 24 months, within the "Terms of Warranty" stated herein, from the invoice date.
  • Page 20 1°C. TANPERA A.Ş. TANPERA GmbH Ludwig-Lange-Straße 9 Şeyhli Mah. Ankara Cad. No: 380/C 67547 Worms / GERMANY 34906 Pendik - İstanbul / TURKEY P. +49 176 21359745 Tel: +90 216 482 11 88 info@tanpera.de - www.tanpera.de info@tanpera.com - www.tanpera.com...

Table of Contents